Unit of Measure
Specifications
Impedance |
N/A 120 ohms |
Impedance Tolerance |
N/A ±10 ohms |
Temperature |
N/A -55 to 200 ºC |
Nom. Velocity of Propagation |
N/A 80 % |
Capacitance |
N/A 13.0 pF/ft |
Root Mean Square (RMS) Dielectric Strength |
N/A 1500 V |
Flammability |
N/A Shall Pass FAA FAR 25.853/869 Complies with RoHS (DIRECTIVE 2002/95EC) |
Maximum Attenuation @ 100 MHz per 100 ft. |
N/A 20.9 dB |
Maximum Attenuation @ 200 MHz per 100 ft. |
N/A 23.6 dB |
Nom. Weight per 1000 ft. |
N/A 5.3 lb |
Construction Details
Conductor |
N/A 30 AWG 7/38 Silver Plated Copper |
Nom. Conductor Diameter |
N/A 0.012 in |
Insulation |
N/A Composite Fluoropolymer - Colors - White & Blue |
Cable Type |
N/A Planetary Twist Per M17 for Balanced Line |
Shield |
N/A 40 AWG Silver Plated Copper Having 90% minimum coverage |
Nom. Shield Diameter |
N/A 0.087 in |
Outer Jacket Material |
N/A PTFE Tape Wrap - HSTF 0.003" MIL Wall |
Nom. Outer Jacket Diameter |
N/A 0.105 in |
Jacket Color |
N/A White |