Unit of Measure
Specifications
Operating Temperature |
N/A -55 to 200 ºC |
Shielded Twisted Pairs (A) |
N/A 4 PLCS |
Conductor (A) |
N/A
AWG 24 (19/36) SPHSCA (2 PLCS) Silver Plated High Strength Copper Alloy |
Insulation (A) |
N/A Strlppable ePTFE Over PTFE (2 PLCS) |
Diameter Over Insulation (A) |
N/A 0.060 |
Colors (A) |
N/A BN x WH BU x WH GN x WH OR x WH |
Shield (A) |
N/A Aluminized Polyimide (Al Out) |
Filler (B) |
N/A FEP/ePTFE |
Diameter Filler (B) |
N/A 0.060 |
Overall Binder (C) |
N/A 0.060 WALL ePTFE |
Drain (D) |
N/A
AWG 24 (19/36) SPHSCA (1 PLC) (Silver Plated High Strength Copper Alloy) |
Overall Shield #1 (E) |
N/A Vacuum Deposited Aluminized Polyimide |
Overall Shield #2 (F) |
N/A AWG 36 (1) SPC Braid |
Overall Jacket (G) |
N/A (0.004) Wall Engineered Fluoropolymer |
Marker Tape (H) |
N/A (0.125) Wide |
Impedance |
N/A 100 ± 15 ohms Measured Differentially |
Time Delay |
N/A 1.24 nsec/ft |
Capacitance |
N/A 12.5 pF/ft |
Nom. Attenuation @ 10 MHz per 100 ft. |
N/A 2.6 dB |
Attenuation @ 100 MHz per 100 ft. |
N/A 8.4 dB |
Attenuation @ 100 MHz per 200 ft. |
N/A 11.9 |
Marking |
N/A Black Print |
Note |
N/A Meets or Exceeds the Requirements of EIA/TIA-568—B.2 Category 6 for all Parameters except Attenuation. |