Unit of Measure
Specifications
Construction |
N/A Conductor: Solid Silver Plated Copper Dielectric: PTFE Tape Inner Braid: Flat Silver Plated Copper 90% min. coverage Jacket: Green Tint FEP Marker Tape: "Harbour Industries LL285 27478" Outer Braid: Round Silver Plated Copper 90% min. coverage |
Center Conductor |
N/A 0.089 ± 0.001 in |
Dielectric Diameter |
N/A 0.245 ± 0.005 in |
Diameter Over Inner Braid |
N/A 0.250 ± 0.005 in |
Diameter Over Outer Braid |
N/A 0.264 ± 0.005 in |
Overall Diameter |
N/A 0.285 ± 0.005 in |
Weight |
N/A 74.0 lb/1000 ft. |
Min. Recommended Bend Radius |
N/A 1.50 in |
Minimum Continuous Length |
N/A 50 ft |
Put-up |
N/A 30 inch wood, multiple lengths per spool |
Operating Temperature |
N/A -55 to +200 ºC |
RoHS Compliance |
N/A Complies with RoHS (Directive 2002/95/EC) |
Test Method |
N/A Connector Type: Male SMA plug IF Band Width: 35 Khz Sampling Plan: PerMil-STD-105 Sweep Time: 6 Sec Test Length: 10 ft Test Points: 801 |
Electrical Characteristics
Impedance |
N/A 50 ±2 ohms |
Capacitance |
N/A 24.5 pF/ft |
Velocity of Propagation |
N/A 84.0 % |
VSWR (Max 400 MHz to 18 GHz) |
N/A 1.35:1 (Gated) |
Attenuation @ 400 MHz per 100 ft. |
N/A Typical: 3.1 dBMaximum: 3.5 dB |
Attenuation @ 1 GHz per 100 ft. |
N/A Maximum: 5.5 dBTypical: 4.9 dB |
Attenuation @ 3 GHz per 100 ft. |
N/A Typical: 8.5 dBMaximum: 9.5 dB |
Attenuation @ 5 GHz per 100 ft. |
N/A Typical: 11.3 dBMaximum: 12.5 dB |
Attenuation @ 10 GHz per 100 ft. |
N/A Typical: 17.1 dBMaximum: 19.0 dB |
Attenuation @ 18 GHz per 100 ft. |
N/A Typical: 23.4 dBMaximum: 26.0 dB |