Unit of Measure
Specifications
Construction |
N/A Center Conductor: Silver plated copper, solid or stranded Dielectric: Expanded PTFE tape Inner Braid: Flat silver plated copper strip Inter layer: Aluminum polyester or polyimide tape Jacket: FEP, translucent colors, solid colors or clear Outer Braid: Round silver plated copper |
Center Conductor |
N/A 0.068 inch (7/0.023 inch) |
Dielectric Diameter |
N/A 0.185 in |
Diameter Over Inner Braid |
N/A 0.195 in |
Diameter Over Interlayer |
N/A 0.200 in |
Diameter Over Outer Braid |
N/A 0.220 in |
Overall Diameter |
N/A 0.270 in |
Weight |
N/A 70.0 lb/1000 ft. |
Min. Recommended Bend Radius |
N/A 1.40 in |
Put-up |
N/A 30 inch wood, multiple lengths per spool |
Operating Temperature |
N/A -55 to +200 ºC |
Electrical Characteristics
Impedance |
N/A 50 ohms |
Capacitance |
N/A 25.0 pF/ft |
Velocity of Propagation |
N/A 80.0 % |
Attenuation @ 400 MHz per 100 ft. |
N/A Typical: 4.3 dBMaximum: 4.5 dB |
Attenuation @ 1 GHz per 100 ft. |
N/A Maximum: 7.3 dBTypical: 6.7 dB |
Attenuation @ 2 GHz per 100 ft. |
N/A Maximum: 10.6 dBTypical: 9.6 dB |
Attenuation @ 3 GHz per 100 ft. |
N/A Typical: 12.0 dBMaximum: 13.4 dB |
Attenuation @ 5 GHz per 100 ft. |
N/A Typical: 15.8 dBMaximum: 18.0 dB |
Attenuation @ 10 GHz per 100 ft. |
N/A Typical: 22.5 dBMaximum: 26.0 dB |
Attenuation @ 18 GHz per 100 ft. |
N/A Typical: 31.1 dBMaximum: 26.0 dB |