High-voltage lead wire with extruded modified FEP (Fluorinated Ethylene Polypropylene) insulation. This insulation provides easy, clean stripping with automated equipment. These wires are intended for use in television receivers, transformers, and other demanding high-voltage applications.
Unit of Measure
Specifications
Conductor Diameter |
N/A 0.084 in2.13 mm |
Insulation |
N/A Extruded modified FEP, 0.018 in (0.46 mm) wall thickness |
Weight |
N/A 7.95 lb/1000 ft.11.8 kg/1000 m. |
Insulation Diameter |
N/A 0.133 in3.38 mm |
Voltage Rating |
N/A 10,000 V |
Conductor |
N/A Nickel-Plated Copper Silver-Plated Copper Tin-Plated Copper |
Stranding |
N/A 19/25 |
Temperature Rating |
N/A 200 ºC |
Colors |
N/A Black Blue Brown Green Grey Orange Red Violet White Yellow |
AWG Size |
N/A 12 |
Max. Resistance @ 20ºC |
N/A 1.81 ohms/1000 ft.5.94 ohms/km. |
Dielectric Withstanding Voltage |
N/A 20,000 V |
Spark Test |
N/A 10,000 V RMS AC, 60 Hz. |
Insulation Tensile Strength |
N/A 2,500 psi |
Min. Insulation Elongation |
N/A 150 % |