Unit of Measure
Specifications
Impedance |
N/A 100 ohms ± 10 |
Capacitance |
N/A 14.5 pF/ft |
Temperature |
N/A -55 to 90 ºC |
Dielectric Volt Rating |
N/A 1.5 KV RMS |
Velocity of Propagation |
N/A 70.0 % |
Near End Cross Talk @ 10 MHz per 100 ft. |
N/A 47.0 dB |
Near End Cross Talk @ 100 MHz per 100 ft. |
N/A 32.0 dB |
Attenuation @ 10 MHz per 100 ft. |
N/A 2.5 dB |
Attenuation @ 100 MHz per 100 ft. |
N/A 7.2 dB |
Flammability |
N/A Shall pass FAA 25.853/869 |
Weight |
N/A 48.0 lb/1000 ft. |
Color |
N/A
1 - White/Blue Stripe & Blue 2 - White/Orange Stripe & Orange 3 - White/Green Stripe & Green 4 - White/Brown Stripe & Brown |
Construction Details
Conductor |
N/A 8 x 24 AWG (19/36) Silver Plated Copper Alloy |
Nom. Conductor Diameter |
N/A 0.0235 ± 0.0025 in |
Insulation |
N/A Extruded FEP |
Nom. Insulation Diameter |
N/A 0.045 ± 0.003 in |
Cable Type |
N/A Cable (4) pairs with spline |
Binder |
N/A PTFE Tape Wrap |
Nom. Binder Diameter |
N/A 0.220 in |
Shield No. 1 |
N/A Aluminum mylar tape, facing out |
Nom. Shield No. 1 Diameter |
N/A 0.225 in |
Shield No. 2 |
N/A Braided silver plated copper, 95% minimum coverage |
Nom. Shield No. 2 Diameter |
N/A 0.241 in |
Jacket |
N/A Extruded DUR-X-THANE ZH |
Nom. Jacket Diameter |
N/A 0.290 in |