These wires are designed for critical circuit applications where wires must operate in extremely harsh environments, under vibration and with direct flame exposure. This heavy-duty, non-asbestos construction offers excellent mechanical performance and abrasion resistance.
Unit of Measure
Specifications
Voltage Rating |
N/A 600 V |
Conductor Size |
N/A 22 AWG |
Conductor Diameter |
N/A 0.031 in0.790 mm |
Conductor |
N/A 27 % Nickel Coated Copper |
Stranding |
N/A 19/34 |
Insulation |
N/A Composite Inorganic Dielectric |
Min. Insulation Diameter |
N/A 0.100 in2.54 mm |
Max. Insulation Diameter |
N/A 0.116 in2.95 mm |
Max. Resistance per 1000 ft. @ 20°C |
N/A 23.70 ohms |
Max. Resistance per Km @20°C |
N/A 77.70 ohms |
Insulation Color |
N/A Black Blue Brown Gray Green Orange Red Violet White Yellow |
Temperature Rating |
N/A -55 to 260 ºC |
Weight |
N/A 10.0 lb/1000 ft.14.9 kg/1000 m. |