These wires have one layer of FEP/polyimide/FEP tape insulation with a polyimide hard coat for increased cut-through and abrasion resistance and a high-strength copper alloy conductor for greater break strength.
Unit of Measure
Specifications
Voltage Rating |
N/A 600 V |
Insulation |
N/A FEP/polyimide/FEP tape with modified aromatic polyimide coating |
Conductor |
N/A Nickel-Plated High-Strength Copper Alloy |
Conductor Size |
N/A 20 AWG |
Min. Conductor Dia. |
N/A 0.037 in0.94 mm |
Max. Conductor Dia. |
N/A 0.040 in1.02 mm |
Stranding |
N/A 19/32 |
Min. Insulation Diameter |
N/A 0.047 in1.19 mm |
Max. Insulation Diameter |
N/A 0.050 in1.27 mm |
Max. Resistance per 1000 ft. @ 20°C |
N/A 11.40 ohms |
Max. Resistance per Km @20°C |
N/A 37.39 ohms |
Temperature Rating |
N/A -55 to 200 ºC |
Weight |
N/A 4.50 lb/1000 ft.6.70 kg/1000 m. |