M27500 Cable-Types MR (M81381/7 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/7 or /8 wires. These component wires have a light-weight insulation of two layers of FEP/polyimide/FEP tape with a polyimide hard coat for increased cut-through and abrasion resistance, and silver-or-nickel-plated copper conductors.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-20 MR 1 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.076 in1.92 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.067 in1.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.23 lb/1000 ft.12.25 kg/1000 m. |
M27500-18 MR 4 N 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 4 | Jacket Diameter N/A 0.172 in4.36 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.163 in4.14 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 35.0 lb/1000 ft.52.10 kg/1000 m. |
M27500-18 MR 3 N 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 3 | Jacket Diameter N/A 0.156 in3.96 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.147 in3.74 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 27.3 lb/1000 ft.40.60 kg/1000 m. |
M27500-18 MR 2 N 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 2 | Jacket Diameter N/A 0.147 in3.72 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.138 in3.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 19.7 lb/1000 ft.29.40 kg/1000 m. |
M27500-18 MR 1 N 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 1 | Jacket Diameter N/A 0.086 in2.18 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.077 in1.96 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.6 lb/1000 ft.15.71 kg/1000 m. |
M27500-16 MR 4 N 12 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 4 | Jacket Diameter N/A 0.186 in4.73 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.177 in4.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 42.3 lb/1000 ft.63.0 kg/1000 m. |
M27500-16 MR 3 N 12 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 3 | Jacket Diameter N/A 0.169 in4.28 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.160 in4.07 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 33.0 lb/1000 ft.49.1 kg/1000 m. |
M27500-16 MR 2 N 12 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 2 | Jacket Diameter N/A 0.159 in4.03 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.150 in3.81 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 23.7 lb/1000 ft.35.30 kg/1000 m. |
M27500-16 MR 1 N 12 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 1 | Jacket Diameter N/A 0.092 in2.33 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.083 in2.11 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.5 lb/1000 ft.18.62 kg/1000 m. |
M27500-14 MR 4 N 12 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 4 | Jacket Diameter N/A 0.217 in5.52 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.209 in5.31 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 62.2 lb/1000 ft.92.60 kg/1000 m. |
M27500-14 MR 3 N 12 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 3 | Jacket Diameter N/A 0.197 in4.99 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.188 in4.78 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 48.0 lb/1000 ft.71.50 kg/1000 m. |
M27500-14 MR 2 N 12 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 2 | Jacket Diameter N/A 0.185 in4.69 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.176 in4.47 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 34.00 lb/1000 ft.50.60 kg/1000 m. |
M27500-14 MR 1 N 12 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 1 | Jacket Diameter N/A 0.105 in2.66 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 17.7 lb/1000 ft.26.40 kg/1000 m. |
M27500-12 MR 4 N 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 4 | Jacket Diameter N/A 0.267 in6.79 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.259 in6.58 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 95.8 lb/1000 ft.143.00 kg/1000 m. |
M27500-12 MR 3 N 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 3 | Jacket Diameter N/A 0.237 in6.03 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.229 in5.81 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 71.4 lb/1000 ft.106 kg/1000 m. |
M27500-12 MR 2 N 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 2 | Jacket Diameter N/A 0.223 in5.66 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.214 in5.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 50.2 lb/1000 ft.74.80 kg/1000 m. |
M27500-12 MR 1 N 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.124 in3.14 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.115 in2.92 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.7 lb/1000 ft.38.19 kg/1000 m. |
M27500-10 MR 4 N 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 4 | Jacket Diameter N/A 0.327 in8.29 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.314 in7.98 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 145.0 lb/1000 ft.216.00 kg/1000 m. |
M27500-10 MR 3 N 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 3 | Jacket Diameter N/A 0.291 in7.39 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.282 in7.17 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 110.0 lb/1000 ft.164.00 kg/1000 m. |
M27500-10 MR 2 N 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 2 | Jacket Diameter N/A 0.269 in6.82 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.260 in6.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 74.2 lb/1000 ft.110.00 kg/1000 m. |
M27500-10 MR 1 N 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.147 in3.72 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.138 in3.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 37.9 lb/1000 ft.56.46 kg/1000 m. |
M27500-26 MR 1 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.058 in1.46 mm | Shield N/A Nickel Plated Copper | Shield Diameter N/A 0.049 in1.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.31 lb/1000 ft.6.41 kg/1000 m. |