M27500 Cable-Types MR (M81381/7 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/7 or /8 wires. These component wires have a light-weight insulation of two layers of FEP/polyimide/FEP tape with a polyimide hard coat for increased cut-through and abrasion resistance, and silver-or-nickel-plated copper conductors.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-12 MR 2 S 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 2 | Jacket Diameter N/A 0.223 in5.66 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.214 in5.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 50.2 lb/1000 ft.74.80 kg/1000 m. |
M27500-12 MR 2 N 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 2 | Jacket Diameter N/A 0.223 in5.66 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.214 in5.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 50.2 lb/1000 ft.74.80 kg/1000 m. |
M27500-10 MR 2 S 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 2 | Jacket Diameter N/A 0.269 in6.82 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.260 in6.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 74.2 lb/1000 ft.110.00 kg/1000 m. |
M27500-10 MR 2 N 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 2 | Jacket Diameter N/A 0.269 in6.82 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.260 in6.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 74.2 lb/1000 ft.110.00 kg/1000 m. |
M27500-26 MR 1 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.058 in1.46 mm | Shield N/A Silver Plated Copper | Shield Diameter N/A 0.049 in1.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.31 lb/1000 ft.6.41 kg/1000 m. |
M27500-26 MR 1 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.058 in1.46 mm | Shield N/A Nickel Plated Copper | Shield Diameter N/A 0.049 in1.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.31 lb/1000 ft.6.41 kg/1000 m. |
M27500-24 MR 1 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.061 in1.54 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.052 in1.32 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.84 lb/1000 ft.7.20 kg/1000 m. |
M27500-24 MR 1 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.061 in1.54 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.052 in1.32 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.84 lb/1000 ft.7.20 kg/1000 m. |
M27500-22 MR 1 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.068 in1.72 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.059 in1.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.82 lb/1000 ft.8.65 kg/1000 m. |
M27500-22 MR 1 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.068 in1.72 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.059 in1.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.82 lb/1000 ft.8.65 kg/1000 m. |
M27500-20 MR 1 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.076 in1.92 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.067 in1.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.23 lb/1000 ft.12.25 kg/1000 m. |
M27500-20 MR 1 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.076 in1.92 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.067 in1.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.23 lb/1000 ft.12.25 kg/1000 m. |
M27500-18 MR 1 S 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 1 | Jacket Diameter N/A 0.086 in2.18 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.077 in1.96 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.6 lb/1000 ft.15.71 kg/1000 m. |
M27500-18 MR 1 N 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 1 | Jacket Diameter N/A 0.086 in2.18 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.077 in1.96 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.6 lb/1000 ft.15.71 kg/1000 m. |
M27500-16 MR 1 S 12 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 1 | Jacket Diameter N/A 0.092 in2.33 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.083 in2.11 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.5 lb/1000 ft.18.62 kg/1000 m. |
M27500-16 MR 1 N 12 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 1 | Jacket Diameter N/A 0.092 in2.33 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.083 in2.11 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.5 lb/1000 ft.18.62 kg/1000 m. |
M27500-14 MR 1 S 12 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 1 | Jacket Diameter N/A 0.105 in2.66 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 17.7 lb/1000 ft.26.40 kg/1000 m. |
M27500-14 MR 1 N 12 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 1 | Jacket Diameter N/A 0.105 in2.66 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 17.7 lb/1000 ft.26.40 kg/1000 m. |
M27500-12 MR 1 S 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.124 in3.14 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.115 in2.92 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.7 lb/1000 ft.38.19 kg/1000 m. |
M27500-12 MR 1 N 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.124 in3.14 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.115 in2.92 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.7 lb/1000 ft.38.19 kg/1000 m. |
M27500-10 MR 1 S 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.147 in3.72 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.138 in3.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 37.9 lb/1000 ft.56.46 kg/1000 m. |
M27500-10 MR 1 N 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.147 in3.72 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.138 in3.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 37.9 lb/1000 ft.56.46 kg/1000 m. |