M27500 Cable-Types NB (M81381/14 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/13 or /14 wires. These component wires have a medium-weight insulationof two layers of FEP/polyimide/FEP tape with a polyimide hard coat for increased cut-through and abrasion resistance. The component wire silver- or nickel-plated high-strength copper alloy conductors.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-24 NB 4 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.126 in3.20 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in2.91 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.7 lb/1000 ft.21.9 kg/1000 m. |
M27500-24 NB 3 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 3 | Jacket Diameter N/A 0.116 in2.92 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.106 in2.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.8 lb/1000 ft.17.50 kg/1000 m. |
M27500-24 NB 2 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 2 | Jacket Diameter N/A 0.109 in2.76 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.100 in2.54 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.34 lb/1000 ft.13.90 kg/1000 m. |
M27500-24 NB 1 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.067 in1.69 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.058 in1.47 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.16 lb/1000 ft.7.67 kg/1000 m. |
M27500-22 NB 4 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.138 in3.50 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.129 in3.28 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 19.4 lb/1000 ft.28.90 kg/1000 m. |
M27500-22 NB 3 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.126 in3.19 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in2.97 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 15.5 lb/1000 ft.23.0 kg/1000 m. |
M27500-22 NB 2 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.119 in3.01 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.110 in2.79 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.40 lb/1000 ft.17.00 kg/1000 m. |
M27500-22 NB 1 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.072 in1.82 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.063 in1.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.37 lb/1000 ft.9.47 kg/1000 m. |
M27500-20 NB 4 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.157 in3.99 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.149 in3.78 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 26.7 lb/1000 ft.39.70 kg/1000 m. |
M27500-20 NB 3 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 3 | Jacket Diameter N/A 0.143 in3.63 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.134 in3.41 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 21.0 lb/1000 ft.31.30 kg/1000 m. |
M27500-20 NB 2 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 2 | Jacket Diameter N/A 0.135 in3.42 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.126 in3.20 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 15.5 lb/1000 ft.23.0 kg/1000 m. |
M27500-20 NB 1 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.080 in2.02 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.071 in1.80 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.52 lb/1000 ft.12.7 kg/1000 m. |
M27500-24 NB 4 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.126 in3.20 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in2.91 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.7 lb/1000 ft.21.9 kg/1000 m. |
M27500-24 NB 3 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 3 | Jacket Diameter N/A 0.116 in2.92 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.106 in2.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.8 lb/1000 ft.17.50 kg/1000 m. |
M27500-24 NB 2 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 2 | Jacket Diameter N/A 0.109 in2.76 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.100 in2.54 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.34 lb/1000 ft.13.90 kg/1000 m. |
M27500-24 NB 1 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.067 in1.69 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.058 in1.47 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.16 lb/1000 ft.7.67 kg/1000 m. |
M27500-22 NB 4 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.138 in3.50 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.129 in3.28 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 19.4 lb/1000 ft.28.90 kg/1000 m. |
M27500-22 NB 3 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.126 in3.19 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in2.97 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 15.5 lb/1000 ft.23.0 kg/1000 m. |
M27500-22 NB 2 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.119 in3.01 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.110 in2.79 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.40 lb/1000 ft.17.00 kg/1000 m. |
M27500-22 NB 1 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.072 in1.82 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.063 in1.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.37 lb/1000 ft.9.47 kg/1000 m. |
M27500-20 NB 4 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.157 in3.99 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.149 in3.78 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 26.7 lb/1000 ft.39.70 kg/1000 m. |
M27500-20 NB 3 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 3 | Jacket Diameter N/A 0.143 in3.63 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.134 in3.41 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 21.0 lb/1000 ft.31.30 kg/1000 m. |
M27500-20 NB 2 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 2 | Jacket Diameter N/A 0.135 in3.42 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.126 in3.20 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 15.5 lb/1000 ft.23.0 kg/1000 m. |
M27500-20 NB 1 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.080 in2.02 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.071 in1.80 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.52 lb/1000 ft.12.7 kg/1000 m. |