M27500 Cable-Types NH (M81381/20 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/19 or /20 wires. These component wires have a light weight insulation of FEP/polyimide/FEP tape with an outer coating of modified aromatic polyimide. The component wires have silver- or nickel-plated high-strength copper alloy conductors.
1 2
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-26 NH 1 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.054 in1.36 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.045 in1.14 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.14 lb/1000 ft.6.16 kg/1000 m. |
M27500-26 NH 1 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.054 in1.36 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.045 in1.14 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.14 lb/1000 ft.6.16 kg/1000 m. |
M27500-24 NH 1 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.059 in1.49 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.050 in1.27 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.79 lb/1000 ft.7.12 kg/1000 m. |
M27500-24 NH 1 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.059 in1.49 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.050 in1.27 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.79 lb/1000 ft.7.12 kg/1000 m. |
M27500-22 NH 1 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.065 in1.64 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.056 in1.42 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.71 lb/1000 ft.8.49 kg/1000 m. |
M27500-22 NH 1 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.065 in1.64 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.056 in1.42 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.71 lb/1000 ft.8.49 kg/1000 m. |
M27500-26 NH 2 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 2 | Jacket Diameter N/A 0.083 in2.10 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.074 in1.88 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.90 lb/1000 ft.8.78 kg/1000 m. |
M27500-26 NH 2 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 2 | Jacket Diameter N/A 0.083 in2.10 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.074 in1.88 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.90 lb/1000 ft.8.78 kg/1000 m. |
M27500-20 NH 1 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.073 in1.85 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.064 in1.63 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 7.53 lb/1000 ft.11.2 kg/1000 m. |
M27500-20 NH 1 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.073 in1.85 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.064 in1.63 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 7.53 lb/1000 ft.11.2 kg/1000 m. |
M27500-26 NH 3 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 3 | Jacket Diameter N/A 0.087 in2.21 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.078 in1.99 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 7.80 lb/1000 ft.11.6 kg/1000 m. |
M27500-26 NH 3 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 3 | Jacket Diameter N/A 0.087 in2.21 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.078 in1.99 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 7.80 lb/1000 ft.11.6 kg/1000 m. |
M27500-24 NH 2 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 2 | Jacket Diameter N/A 0.093 in2.35 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.084 in2.13 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 7.84 lb/1000 ft.11.7 kg/1000 m. |
M27500-24 NH 2 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 2 | Jacket Diameter N/A 0.093 in2.35 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.084 in2.13 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 7.84 lb/1000 ft.11.7 kg/1000 m. |
M27500-26 NH 4 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.095 in2.40 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.086 in2.18 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.92 lb/1000 ft.14.80 kg/1000 m. |
M27500-26 NH 4 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.095 in2.40 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.086 in2.18 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.92 lb/1000 ft.14.80 kg/1000 m. |
M27500-22 NH 2 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.105 in2.66 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.93 lb/1000 ft.14.80 kg/1000 m. |
M27500-22 NH 2 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.105 in2.66 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.93 lb/1000 ft.14.80 kg/1000 m. |
M27500-24 NH 3 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 3 | Jacket Diameter N/A 0.098 in2.48 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.089 in2.26 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.96 lb/1000 ft.14.80 kg/1000 m. |
M27500-24 NH 3 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 3 | Jacket Diameter N/A 0.098 in2.48 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.089 in2.26 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.96 lb/1000 ft.14.80 kg/1000 m. |
M27500-24 NH 4 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.107 in2.71 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.098 in2.49 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.5 lb/1000 ft.18.70 kg/1000 m. |
M27500-24 NH 4 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.107 in2.71 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.098 in2.49 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.5 lb/1000 ft.18.70 kg/1000 m. |
M27500-22 NH 3 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.111 in2.81 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.102 in2.59 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.4 lb/1000 ft.19.9 kg/1000 m. |
M27500-22 NH 3 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.111 in2.81 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.102 in2.59 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.4 lb/1000 ft.19.9 kg/1000 m. |
M27500-20 NH 2 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 2 | Jacket Diameter N/A 0.121 in3.06 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.112 in2.84 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.8 lb/1000 ft.20.60 kg/1000 m. |
1 2