M27500 Cable-Types WL (M22759/88 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape covered by a PTFE tape outer layer, incorporating MIL-DTL-22759/86, /87, /88 wires. These component wires have a light-weight composite insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape and silver, nickel, or tin-plated copper conductors.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-10 WL 1 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.146 in3.70 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.48 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 48.4 lb/1000 ft.57.10 kg/1000 m. |
M27500-10 WL 2 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 2 | Jacket Diameter N/A 0.271 in6.87 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.262 in6.65 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 74.7 lb/1000 ft.111.00 kg/1000 m. |
M27500-10 WL 3 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 3 | Jacket Diameter N/A 0.289 in7.34 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.280 in7.12 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 110.0 lb/1000 ft.164.00 kg/1000 m. |
M27500-10 WL 4 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 4 | Jacket Diameter N/A 0.324 in8.23 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.312 in7.90 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 143.0 lb/1000 ft.213.00 kg/1000 m. |
M27500-12 WL 1 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.123 in3.12 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.114 in2.90 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 26.3 lb/1000 ft.39.00 kg/1000 m. |
M27500-12 WL 2 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 2 | Jacket Diameter N/A 0.221 in5.60 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.212 in5.38 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 50.2 lb/1000 ft.74.70 kg/1000 m. |
M27500-12 WL 3 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 3 | Jacket Diameter N/A 0.235 in5.98 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.227 in5.76 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 71.4 lb/1000 ft.106 kg/1000 m. |
M27500-12 WL 4 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 4 | Jacket Diameter N/A 0.265 in6.73 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.256 in6.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 93.1 lb/1000 ft.138.00 kg/1000 m. |
M27500-14 WL 1 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 1 | Jacket Diameter N/A 0.103 in2.61 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.094 in2.39 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18 lb/1000 ft.26.80 kg/1000 m. |
M27500-14 WL 2 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 2 | Jacket Diameter N/A 0.181 in4.59 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.172 in4.37 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 34.2 lb/1000 ft.50.90 kg/1000 m. |
M27500-14 WL 3 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 3 | Jacket Diameter N/A 0.192 in4.89 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.184 in4.67 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 47.9 lb/1000 ft.71.30 kg/1000 m. |
M27500-14 WL 4 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 4 | Jacket Diameter N/A 0.213 in5.40 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.204 in5.20 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 61.8 lb/1000 ft.92.00 kg/1000 m. |
M27500-16 WL 1 N 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 1 | Jacket Diameter N/A 0.090 in2.28 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.081 in2.06 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.0 lb/1000 ft.19.40 kg/1000 m. |
M27500-16 WL 2 N 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 2 | Jacket Diameter N/A 0.155 in3.93 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.146 in3.71 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.3 lb/1000 ft.36.10 kg/1000 m. |
M27500-16 WL 3 N 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 3 | Jacket Diameter N/A 0.164 in4.18 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.156 in3.96 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 33.9 lb/1000 ft.50.40 kg/1000 m. |
M27500-16 WL 4 N 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 4 | Jacket Diameter N/A 0.181 in4.60 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.173 in4.40 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 43.4 lb/1000 ft.64.60 kg/1000 m. |
M27500-18 WL 1 N 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 1 | Jacket Diameter N/A 0.083 in2.10 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.074 in1.88 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.1 lb/1000 ft.16.50 kg/1000 m. |
M27500-18 WL 2 N 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 2 | Jacket Diameter N/A 0.141 in3.57 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.132 in3.35 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 20.3 lb/1000 ft.30.1 kg/1000 m. |
M27500-18 WL 3 N 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 3 | Jacket Diameter N/A 0.149 in3.79 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.141 in3.57 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 27.9 lb/1000 ft.41.60 kg/1000 m. |
M27500-18 WL 4 N 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 4 | Jacket Diameter N/A 0.164 in4.18 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.156 in4.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 35.5 lb/1000 ft.52.90 kg/1000 m. |
M27500-20 WL 1 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.075 in1.90 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.066 in1.68 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.17 lb/1000 ft.12.2 kg/1000 m. |
M27500-20 WL 2 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 2 | Jacket Diameter N/A 0.125 in3.17 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.116 in2.95 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.8 lb/1000 ft.22.10 kg/1000 m. |
M27500-20 WL 3 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 3 | Jacket Diameter N/A 0.132 in3.36 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.124 in3.14 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 20.1 lb/1000 ft.30.0 kg/1000 m. |
M27500-20 WL 4 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.145 in3.69 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.6 lb/1000 ft.38.00 kg/1000 m. |
M27500-22 WL 1 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.067 in1.69 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.058 in1.47 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.17 lb/1000 ft.9.18 kg/1000 m. |