M27500 Cable-Types WM (M22759/89 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape covered by a PTFE tape outer layer, incorporating MIL-DTL-22759/89 or /90 wires. These component wires have a light-weight composite insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape and silver-or-nickel plated high-strength copper alloy conductors.
1 2
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-20 WM 4 S 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.145 in3.69 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.6 lb/1000 ft.38.00 kg/1000 m. |
M27500-22 WM 4 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.126 in3.20 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in3.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-22 WM 4 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.126 in3.20 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in3.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-24 WM 4 N 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.1 lb/1000 ft.19.40 kg/1000 m. |
M27500-24 WM 4 S 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.1 lb/1000 ft.19.40 kg/1000 m. |
M27500-26 WM 4 N 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.102 in2.58 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.093 in2.40 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.6 lb/1000 ft.15.70 kg/1000 m. |
M27500-26 WM 4 S 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.102 in2.58 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.093 in2.40 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.6 lb/1000 ft.15.70 kg/1000 m. |
1 2