Type ET Cables - MIL-W-16878/6 Components
MIL-W-16878 (Type E, EE and ET) MIL/Aero Cables
Type ET cables are shielded and jacketed cables with extruded FEP or PTFE tape jackets, incorporating MIL-W-16878/4 wires.
« 6
Item # |
Conductor Size |
Conductor |
Number of Wires |
Stranding |
Shield Diameter |
Jacket Material |
Jacket Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|---|
W252-363F | Conductor Size N/A 36 AWG | Conductor N/A Silver-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/44 | Shield Diameter N/A 0.061 in1.56 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.079 in2.02 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.03 lb/1000 ft.8.97 kg/1000 m. |
W252-204TNIC | Conductor Size N/A 20 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 19/32 | Shield Diameter N/A 0.144 in3.64 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.162 in4.10 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 31.0 lb/1000 ft.46.10 kg/1000 m. |
W252-204FNIC | Conductor Size N/A 20 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 19/32 | Shield Diameter N/A 0.144 in3.64 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.162 in4.10 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 31.0 lb/1000 ft.46.10 kg/1000 m. |
W252-224TNIC | Conductor Size N/A 22 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 19/34 | Shield Diameter N/A 0.124 in3.16 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.142 in3.61 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 22.4 lb/1000 ft.33.30 kg/1000 m. |
W252-224FNIC | Conductor Size N/A 22 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 19/34 | Shield Diameter N/A 0.124 in3.16 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.142 in3.61 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 22.4 lb/1000 ft.33.30 kg/1000 m. |
W252-244TNIC | Conductor Size N/A 24 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 19/36 | Shield Diameter N/A 0.110 in2.79 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.128 in3.25 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 17.3 lb/1000 ft.25.70 kg/1000 m. |
W252-244FNIC | Conductor Size N/A 24 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 19/36 | Shield Diameter N/A 0.110 in2.79 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.128 in3.25 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 17.3 lb/1000 ft.25.70 kg/1000 m. |
W252-264TNIC | Conductor Size N/A 26 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 19/38 | Shield Diameter N/A 0.098 in2.48 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.116 in2.94 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 14.2 lb/1000 ft.21.10 kg/1000 m. |
W252-264FNIC | Conductor Size N/A 26 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 19/38 | Shield Diameter N/A 0.098 in2.48 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.116 in2.94 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.2 lb/1000 ft.21.10 kg/1000 m. |
W252-284TNIC | Conductor Size N/A 28 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/36 | Shield Diameter N/A 0.088 in2.24 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.106 in2.69 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 11.9 lb/1000 ft.17.70 kg/1000 m. |
W252-284FNIC | Conductor Size N/A 28 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/36 | Shield Diameter N/A 0.088 in2.24 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.106 in2.69 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.9 lb/1000 ft.17.70 kg/1000 m. |
W252-304TNIC | Conductor Size N/A 30 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/38 | Shield Diameter N/A 0.081 in2.05 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.099 in2.51 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 9.48 lb/1000 ft.14.10 kg/1000 m. |
W252-304FNIC | Conductor Size N/A 30 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/38 | Shield Diameter N/A 0.081 in2.05 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.099 in2.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 9.48 lb/1000 ft.14.10 kg/1000 m. |
W252-324TNIC | Conductor Size N/A 32 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/40 | Shield Diameter N/A 0.076 in1.93 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.094 in2.39 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 8.50 lb/1000 ft.12.6 kg/1000 m. |
W252-324FNIC | Conductor Size N/A 32 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/40 | Shield Diameter N/A 0.076 in1.93 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.094 in2.39 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.50 lb/1000 ft.12.6 kg/1000 m. |
W252-344TNIC | Conductor Size N/A 34 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/42 | Shield Diameter N/A 0.064 in1.62 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.082 in2.08 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 6.15 lb/1000 ft.9.15 kg/1000 m. |
W252-344FNIC | Conductor Size N/A 34 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/42 | Shield Diameter N/A 0.064 in1.62 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.082 in2.08 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.15 lb/1000 ft.9.15 kg/1000 m. |
W252-364TNIC | Conductor Size N/A 36 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/44 | Shield Diameter N/A 0.061 in1.56 mm | Jacket Material N/A PTFE Tape | Jacket Diameter N/A 0.079 in2.02 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 6.03 lb/1000 ft.8.97 kg/1000 m. |
W252-364FNIC | Conductor Size N/A 36 AWG | Conductor N/A Nickel-Plated Copper | Number of Wires N/A 4 | Stranding N/A 7/44 | Shield Diameter N/A 0.061 in1.56 mm | Jacket Material N/A Extruded FEP | Jacket Diameter N/A 0.079 in2.02 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.03 lb/1000 ft.8.97 kg/1000 m. |
« 6