SLT-28 Super Lightweight Wire/Cables
Space LT Super Lightweight Cables
Super Lightweight Cables XLETFE 150°C/450 V
Conductors: Conductor shall be built per Whitmor/Wirenetics drawing SLT-1.
Cabling: The required number of conductors, determined by the cable designation, will be cabled with a left-hand lay. The lay length of the individual conductors shall be not less than 8 nor more than 16 times the outside major axis diameter of the unshielded, unjacketed cable.
Shield: When a shielded construction is called for in the cable designation, either a closely woven round strand braid or a flat strand braid will be used over the conductors.
Jacket: When a jacketed construction is called for in the cable designation, the wall thickness will be a nominal of .004" - .008" of either ETFE or irradiation crosslinked ETFE.
Conductors: Conductor shall be built per Whitmor/Wirenetics drawing SLT-1.
Cabling: The required number of conductors, determined by the cable designation, will be cabled with a left-hand lay. The lay length of the individual conductors shall be not less than 8 nor more than 16 times the outside major axis diameter of the unshielded, unjacketed cable.
Shield: When a shielded construction is called for in the cable designation, either a closely woven round strand braid or a flat strand braid will be used over the conductors.
Jacket: When a jacketed construction is called for in the cable designation, the wall thickness will be a nominal of .004" - .008" of either ETFE or irradiation crosslinked ETFE.
Item # |
Max. Diameter |
Max. Weight |
Percentage of Shield Coverage |
Color Code |
Conductor Type |
# of Conductors |
Shield Type |
---|---|---|---|---|---|---|---|
SPACE-28SC3S23 | Max. Diameter N/A 0.084 in | Max. Weight N/A 6.30 lb/1000 ft. | Percentage of Shield Coverage N/A 85 % | Color Code N/A (-) White Base with Stripes | Conductor Type N/A Silver Plated HSCA | # of Conductors N/A 3 | Shield Type N/A Silver Plated Copper, Round |
SPACE-28SC2S23 | Max. Diameter N/A 0.080 in | Max. Weight N/A 5.04 lb/1000 ft. | Percentage of Shield Coverage N/A 85 % | Color Code N/A (-) White Base with Stripes | Conductor Type N/A Silver Plated HSCA | # of Conductors N/A 2 | Shield Type N/A Silver Plated Copper, Round |
SPACE-28SC1S23 | Max. Diameter N/A 0.054 in | Max. Weight N/A 3.10 lb/1000 ft. | Percentage of Shield Coverage N/A 85 % | Color Code N/A (-) White Base with Stripes | Conductor Type N/A Silver Plated HSCA | # of Conductors N/A 1 | Shield Type N/A Silver Plated Copper, Round |
SPACE-28SC3U00 | Max. Diameter N/A 0.055 in | Max. Weight N/A 2.41 lb/1000 ft. | Percentage of Shield Coverage N/A 85 % | Color Code N/A (-) White Base with Stripes | Conductor Type N/A Silver Plated HSCA | # of Conductors N/A 3 | Shield Type N/A No Shield |
SPACE-28SC2U00 | Max. Diameter N/A 0.050 in | Max. Weight N/A 1.62 lb/1000 ft. | Percentage of Shield Coverage N/A 85 % | Color Code N/A (-) White Base with Stripes | Conductor Type N/A Silver Plated HSCA | # of Conductors N/A 2 | Shield Type N/A No Shield |