Unit of Measure

Specifications

Temperature

N/A -70 to 150 ºC

Delay Skew

N/A 1.29 Ps/foot

Nom. Impedance

N/A 100 ohms

Nom. Attenuation @ 10 MHz per 100 ft.

N/A 2.0 dB

Nom. Attenuation @ 100 MHz per 100 ft.

N/A 6.5 dB

DWV

N/A 750 VAC RMS

Spark Test

N/A 1500 V RMS

Velocity of Propagation

N/A 79 %

Insulation Resistance

N/A 5000 Mohms/mft

Capacitance

N/A 13.0 pF/ft

Flammability

N/A Shall Pass FAA FAR 25.869

Color Code

N/A Blue White

Shield No. 1

N/A Braided Flat Tin Plated Copper - 92% Minimum Coverage

Nom. Shield No. 1 Diameter

N/A 0.140 in

Shield No. 2

N/A Braided Round Tin Plated Copper - 85% Minimum Coverage

Nom. Shield No. 2 Diameter

N/A 0.160 in

Jacket

N/A Extruded FEP - Color - Translucent Blue

Jacket Tolerance

N/A ±0.010 in

Maximum Weight

N/A 30.0 lb/Mft

Construction Details

Conductor

N/A 22 AWG 19/34 Silver Plated Copper

Nom. Conductor Diameter

N/A 0.028 to 0.032 in

Insulation

N/A LTE Extruded Expanded PTFE with Sintered PTFE Tape Jacket

Nom. Insulation Diameter

N/A 0.065 to 0.071 in

Cable Type

N/A Planetary Cable Conductors for Balanced Line with Fillers

Nom. Outer Jacket Diameter

N/A 0.182 in

Jacket Print

N/A W-5517-5053 Marker Tape Under Jacket

Packaging

Packaging

N/A To be supplied on bulk reels, 100 feet minimum lengths