MIL-W-16878/12 (type KK) equivalent wires have extruded FEP insulation (heavy wall thickness) for high-temperature applications.These wires have tin- plated copper conductors for economy.
Unit of Measure
Specifications
Voltage Rating |
N/A 1000 V |
Insulation |
N/A Extruded FEP, wall thickness 0.015 inch (0.38mm) |
Conductor |
N/A Tin-Plated Copper |
Conductor Size |
N/A 12 AWG |
Conductor Diameter |
N/A 0.084 in2.130 mm |
Stranding |
N/A 19/25 |
Min. Insulation Diameter |
N/A 0.117 in2.97 mm |
Max. Resistance per 1000 ft. @ 20°C |
N/A 1.92 ohms |
Max. Resistance per Km @20°C |
N/A 6.300 ohms |
Options |
N/A Silver - or nickel-plated copper conductor; silver or nickel-plated high-strength copper alloy conductor; sodium napthalene etched insulation for bondability. Also available to NEMA HP-4-KK. |
Temperature Rating |
N/A -55 to 150 ºC |
Weight |
N/A 24.8 lb/1000 ft.36.9 kg/1000 m. |