Leading provider
of high-performance wire,
cable and tubing since 1959
Toll Free:(800) 822-WIRE
Local: (661) 257-2400
Mil-C-17 cables are constructed with either solid or stranded silver plated conductors insulated with an extruded PTFE (polytetrafluoroethylene) dielectric. The outstanding electrical and mechanical properties of PTFE over a broad range of temperatures and frequencies make these coaxial cables the standard for a wide range of military and commercial applications.
26 - 50 of 67 | Results Per Page | View | Unit of Measure
1 2 3 

Item #

Conductor Diameter

Impedance

Jacket Diameter

Capacitance

Comments

N/A SC 0.033 (0.84) N/A 50 ± 2 ohms66 Vp % N/A PE-IIIA 0.245 inPE-IIIA 6.22 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-water blocked M17/134-00001
N/A SCBeCu 7/0.004 0.0120 (0.30) N/A 95 ± 5 ohms69.5 Vp % N/A PFA-XIII 0.141 inPFA-XIII 3.58 mm N/A 15.4 pF/ft50.5 pF/m N/A High Strength M17/95-RG180
N/A SCCS 0.0113 (0.29) N/A 50 ± 2.5 ohms69.5 Vp % N/A None N/A 29.4 pF/ft96.5 pF/m N/A .047” Semirigid
N/A SCCS 0.0113 (0.29) N/A 50 ± 2.5 ohms69.5 Vp % N/A None N/A 29.4 pF/ft96.5 pF/m N/A Tinplated M17/151-00001
N/A SCCS 7/0.0067 0.0201 (0.51) N/A 50 ± 2 ohms69.5 Vp % N/A FEP-IX 0.114 inFEP-IX 2.90 mm N/A 29.4 pF/ft96.5 pF/m N/A Double Shielded M17/113-RG316
N/A SCCS 7/0.004 0.012 (0.30) N/A 95 ± 3 ohms69.5 Vp % N/A FEP-IX 0.184 inFEP-IX 4.67 mm N/A 15.4 pF/ft50.5 pF/m N/A Use up to 3000 MHz maximum
N/A TC 19/0.0072 0.0355 (0.90) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.195 inXLPE 4.95 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/28-RG58
N/A CCS 0.0226 (0.57) N/A 75 ± 3 ohms66 Vp % N/A XLPE 0.242 inXLPE 6.15 mm N/A 20.6 pF/ft67.6 pF/m N/A Non-halogen Low smoke M17/29-RG59
N/A CCS 0.0253 (0.64) N/A 93 ± 5 ohms81 Vp % N/A XLPE 0.242 inXLPE 6.15 mm N/A 13.5 pF/ft44.3 pF/m N/A Non-halogen Low smoke M17/30-RG62
N/A 2C:TC 7/0.0126 0.0378 (0.96) N/A 75 ± 3 ohms68 Vp % N/A XLPE 0.235 inXLPE 5.97 mm N/A 19.6 pF/ft64.3 pF/m N/A Non-halogen Low smoke M17/45-RG108
N/A TC 27/0.005 0.0308 (0.78) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.160 inXLPE 4.06 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/54-RG122
N/A BC 7/0.0296 0.0888 (2.26) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.405 inXLPE 10.29 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/74-RG213
N/A SC 7/0.0296 0.0888 (2.26) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.425 inXLPE 10.80 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/75-RG214
N/A SC 0.0350 (0.89) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.212 inXLPE 5.38 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/84-RG223
N/A CCS 7/0.0063 0.0189 (0.48) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.110 inXLPE 2.79 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/119-RG174
N/A BCCS 0.0253 (0.64) N/A 125 ± 6 ohms86 Vp % N/A XLPE 0.405 inXLPE 10.29 mm N/A 11.0 pF/ft36.1 pF/m N/A Non halogen Low smoke M17/31-RG63
N/A 0.037 in0.694 mm N/A 50 ohms N/A 0.195 in4.95 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.012 in0.057 mm N/A 50 ohms N/A 0.071 in1.80 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.012 in0.057 mm N/A 50 ohms N/A 0.071 in1.80 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.012 in0.057 mm N/A 75 ohms N/A 0.100 in2.54 mm N/A 23.0 pF/ft75.4 pF/m N/A
N/A 0.012 in0.057 mm N/A 95 ohms N/A 0.141 in3.58 mm N/A 17.4 pF/ft57.1 pF/m N/A
N/A 0.025 in0.324 mm N/A 75 ohms N/A 0.202 in5.13 mm N/A 22.0 pF/ft72.2 pF/m N/A
N/A 0.037 in0.694 mm N/A 50 ohms N/A 0.170 in4.32 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.059 in1.760 mm N/A 50 ohms N/A 0.280 in7.11 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.020 in0.159 mm N/A 50 ohms N/A 0.098 in2.49 mm N/A 32.0 pF/ft105.0 pF/m N/A
26 - 50 of 67 | Results Per Page | View | Unit of Measure
1 2 3