Mil-C-17 cables are constructed with either solid or stranded silver plated conductors insulated with an extruded PTFE (polytetrafluoroethylene) dielectric. The outstanding electrical and mechanical properties of PTFE over a broad range of temperatures and frequencies make these coaxial cables the standard for a wide range of military and commercial applications.
1 - 25 of 67 | Results Per Page | View | Unit of Measure
1 2 3 

Item #

Conductor Diameter

Impedance

Jacket Diameter

Capacitance

Comments

Sort by
N/A BC 0.106 (2.69) N/A 50 ± 2 ohms66 Vp % N/A PVC-IIA 0.545 inPVC-IIA 13.84 mm N/A 30.8 pF/ft101.1 pF/m N/A Use: M17-192-00001 LS/LT Jacket
N/A SC 7/0.0296 0.0888 (2.26) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.425 inXLPE 10.80 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/75-RG214
N/A SC 7/0.0296 inch 0.0888 (2.26) N/A 50 ± 2 ohms66 Vp % N/A PVC-IIA 0.425 inPVC-IIA 10.80 mm N/A 30.8 pF/ft101.1 pF/m N/A Use: M17/190-00001 LS/LT Jacket
N/A BCCS 0.0253 (0.64) N/A 125 ± 6 ohms86 Vp % N/A XLPE 0.405 inXLPE 10.29 mm N/A 11.0 pF/ft36.1 pF/m N/A Non halogen Low smoke M17/31-RG63
N/A BC 7/0.0296 0.0888 (2.26) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.405 inXLPE 10.29 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/74-RG213
N/A BC 7/0.0296 inch 0.0888 (2.26) N/A 50 ± 2 ohms66 Vp % N/A PVC-IIA 0.405 inPVC-IIA 10.29 mm N/A 30.8 pF/ft101.1 pF/m N/A Use: M/17189-00001 LS/LT Jacket
N/A TC 7/0.0159 inch 0.0477 (1.21) N/A 75 ± 3 ohms66 Vp % N/A PVC-IIA 0.405 inPVC-IIA 10.29 mm N/A 20.8 pF/ft67.6 pF/m N/A Use: M17/181-00001 LS/LT Jacket
N/A 0.094 in3.450 mm N/A 50 ohms N/A 0.390 in9.91 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.094 in3.450 mm N/A 50 ohms N/A 0.390 in9.91 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.059 in1.760 mm N/A 50 ohms N/A 0.280 in7.11 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.059 in1.760 mm N/A 50 ohms N/A 0.280 in7.11 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A SC 0.033 (0.84) N/A 50 ± 2 ohms66 Vp % N/A PE-IIIA 0.245 inPE-IIIA 6.22 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-water blocked M17/134-00001
N/A CCS 0.0226 (0.57) N/A 75 ± 3 ohms66 Vp % N/A XLPE 0.242 inXLPE 6.15 mm N/A 20.6 pF/ft67.6 pF/m N/A Non-halogen Low smoke M17/29-RG59
N/A CCS 0.0253 (0.64) N/A 93 ± 5 ohms81 Vp % N/A XLPE 0.242 inXLPE 6.15 mm N/A 13.5 pF/ft44.3 pF/m N/A Non-halogen Low smoke M17/30-RG62
N/A CCS 0.0226 (0.57) N/A 75 ± 3 ohms66 Vp % N/A PVC-IIA 0.242 inPVC-IIA 6.15 mm N/A 20.6 pF/ft67.6 pF/m N/A Use: M17/184-00001 LS/LT Jacket
N/A CCS 0.0253 (0.64) N/A 93 ± 5 ohms81 Vp % N/A PVC-IIA 0.242 inPVC-IIA 6.15 mm N/A 13.5 pF/ft44.3 pF/m N/A Use: M17/185-00001 LS/LT Jacket
N/A 2C:TC 7/0.0126 0.0378 (0.96) N/A 75 ± 3 ohms68 Vp % N/A XLPE 0.235 inXLPE 5.97 mm N/A 19.6 pF/ft64.3 pF/m N/A Non-halogen Low smoke M17/45-RG108
N/A 2:TC 7/0.0126 inch 0.0378 (0.96) N/A 78 ± 7 ohms68 Vp % N/A PVC-IIA 0.235 inPVC-IIA 5.97 mm N/A 19.6 pF/ft64.3 pF/m N/A Use: M17/186-00001 LS/LT Jacket
N/A SC 0.0350 (0.89) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.212 inXLPE 5.38 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/84-RG223
N/A SC 0.035 (0.89) N/A 50 ± 2 ohms66 Vp % N/A PVC-IIA 0.212 inPVC-IIA 5.38 mm N/A 30.8 pF/ft101.1 pF/m N/A Use: M17/194-00001 LS/LT Jacket
N/A 0.025 in0.324 mm N/A 75 ohms N/A 0.202 in5.13 mm N/A 22.0 pF/ft72.2 pF/m N/A
N/A TC 19/0.0072 0.0355 (0.90) N/A 50 ± 2 ohms66 Vp % N/A XLPE 0.195 inXLPE 4.95 mm N/A 30.8 pF/ft101.1 pF/m N/A Non-halogen Low smoke M17/28-RG58
N/A TC 19/0.0072 inch 0.0355 (0.090) N/A 50 ± 2 ohms66 Vp % N/A PVC-IIA 0.195 inPVC-IIA 4.95 mm N/A 30.8 pF/ft101.1 pF/m N/A Use: M17/183-00001 LS/LT Jacket
N/A 0.037 in0.694 mm N/A 50 ohms N/A 0.195 in4.95 mm N/A 32.0 pF/ft105.0 pF/m N/A
N/A 0.038 in0.616 mm N/A 50 ohms N/A 0.195 in4.95 mm N/A 32.0 pF/ft105.0 pF/m N/A