Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/7 or /8 wires. These component wires have a light-weight insulation of two layers of FEP/polyimide/FEP tape with a polyimide hard coat for increased cut-through and abrasion resistance, and silver-or-nickel-plated copper conductors.
26 - 50 of 72 | Results Per Page | View | Unit of Measure
1 2 3 

Item #

Conductor Size

Stranding

Number of Wires

Jacket Diameter

Shield

Shield Diameter

Temperature Rating

Weight

Sort by
N/A 22 AWG N/A 19/34 N/A 2 N/A 0.111 in2.81 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.102 in2.59 mm N/A -55 to 200 ºC N/A 10.8 lb/1000 ft.16.1 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 3 N/A 0.117 in2.97 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.108 in2.75 mm N/A -55 to 200 ºC N/A 13.9 lb/1000 ft.20.7 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 4 N/A 0.128 in3.26 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.120 in3.05 mm N/A -55 to 200 ºC N/A 18.1 lb/1000 ft.27.00 kg/1000 m.
N/A 24 AWG N/A 19/36 N/A 1 N/A 0.061 in1.54 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.052 in1.32 mm N/A -55 to 200 ºC N/A 4.84 lb/1000 ft.7.20 kg/1000 m.
N/A 24 AWG N/A 19/36 N/A 2 N/A 0.097 in2.45 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.088 in2.24 mm N/A -55 to 200 ºC N/A 7.96 lb/1000 ft.11.8 kg/1000 m.
N/A 24 AWG N/A 19/36 N/A 3 N/A 0.102 in2.59 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.093 in2.37 mm N/A -55 to 200 ºC N/A 10.7 lb/1000 ft.15.9 kg/1000 m.
N/A 24 AWG N/A 19/36 N/A 4 N/A 0.111 in2.83 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.103 in2.62 mm N/A -55 to 200 ºC N/A 12.8 lb/1000 ft.19.0 kg/1000 m.
N/A 26 AWG N/A 19/38 N/A 1 N/A 0.058 in1.46 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.049 in1.24 mm N/A -55 to 200 ºC N/A 4.31 lb/1000 ft.6.41 kg/1000 m.
N/A 26 AWG N/A 19/38 N/A 2 N/A 0.091 in2.30 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.082 in2.08 mm N/A -55 to 200 ºC N/A 6.85 lb/1000 ft.10.20 kg/1000 m.
N/A 26 AWG N/A 19/38 N/A 3 N/A 0.096 in2.43 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.087 in2.21 mm N/A -55 to 200 ºC N/A 8.41 lb/1000 ft.12.5 kg/1000 m.
N/A 26 AWG N/A 19/38 N/A 4 N/A 0.104 in2.65 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.096 in2.44 mm N/A -55 to 200 ºC N/A 10.5 lb/1000 ft.15.70 kg/1000 m.
N/A 10 AWG N/A 37/26 N/A 1 N/A 0.147 in3.72 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.138 in3.51 mm N/A -55 to 200 ºC N/A 37.9 lb/1000 ft.56.46 kg/1000 m.
N/A 10 AWG N/A 37/26 N/A 2 N/A 0.269 in6.82 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.260 in6.60 mm N/A -55 to 200 ºC N/A 74.2 lb/1000 ft.110.00 kg/1000 m.
N/A 10 AWG N/A 37/26 N/A 3 N/A 0.291 in7.39 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.282 in7.17 mm N/A -55 to 200 ºC N/A 110.0 lb/1000 ft.164.00 kg/1000 m.
N/A 10 AWG N/A 37/26 N/A 4 N/A 0.327 in8.29 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.314 in7.98 mm N/A -55 to 200 ºC N/A 145.0 lb/1000 ft.216.00 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 1 N/A 0.124 in3.14 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.115 in2.92 mm N/A -55 to 200 ºC N/A 25.7 lb/1000 ft.38.19 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 2 N/A 0.223 in5.66 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.214 in5.44 mm N/A -55 to 200 ºC N/A 50.2 lb/1000 ft.74.80 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 3 N/A 0.237 in6.03 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.229 in5.81 mm N/A -55 to 200 ºC N/A 71.4 lb/1000 ft.106 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 4 N/A 0.267 in6.79 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.259 in6.58 mm N/A -55 to 200 ºC N/A 95.8 lb/1000 ft.143.00 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 1 N/A 0.105 in2.66 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.096 in2.44 mm N/A -55 to 200 ºC N/A 17.7 lb/1000 ft.26.40 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 2 N/A 0.185 in4.69 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.176 in4.47 mm N/A -55 to 200 ºC N/A 34.00 lb/1000 ft.50.60 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 3 N/A 0.197 in4.99 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.188 in4.78 mm N/A -55 to 200 ºC N/A 48.0 lb/1000 ft.71.50 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 4 N/A 0.217 in5.52 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.209 in5.31 mm N/A -55 to 200 ºC N/A 62.2 lb/1000 ft.92.60 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 1 N/A 0.092 in2.33 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.083 in2.11 mm N/A -55 to 200 ºC N/A 12.5 lb/1000 ft.18.62 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 2 N/A 0.159 in4.03 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.150 in3.81 mm N/A -55 to 200 ºC N/A 23.7 lb/1000 ft.35.30 kg/1000 m.