Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/7 or /8 wires. These component wires have a light-weight insulation of two layers of FEP/polyimide/FEP tape with a polyimide hard coat for increased cut-through and abrasion resistance, and silver-or-nickel-plated copper conductors.
26 - 50 of 72 | Results Per Page | View | Unit of Measure
1 2 3 

Item #

Conductor Size

Stranding

Number of Wires

Jacket Diameter

Shield

Shield Diameter

Temperature Rating

Weight

Sort by
N/A 16 AWG N/A 19/29 N/A 1 N/A 0.092 in2.33 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.083 in2.11 mm N/A -55 to 200 ºC N/A 12.5 lb/1000 ft.18.62 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 2 N/A 0.159 in4.03 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.150 in3.81 mm N/A -55 to 200 ºC N/A 23.7 lb/1000 ft.35.30 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 2 N/A 0.159 in4.03 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.150 in3.81 mm N/A -55 to 200 ºC N/A 23.7 lb/1000 ft.35.30 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 3 N/A 0.169 in4.28 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.160 in4.07 mm N/A -55 to 200 ºC N/A 33.0 lb/1000 ft.49.1 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 3 N/A 0.169 in4.28 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.160 in4.07 mm N/A -55 to 200 ºC N/A 33.0 lb/1000 ft.49.1 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 4 N/A 0.186 in4.73 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.177 in4.50 mm N/A -55 to 200 ºC N/A 42.3 lb/1000 ft.63.0 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 4 N/A 0.186 in4.73 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.177 in4.50 mm N/A -55 to 200 ºC N/A 42.3 lb/1000 ft.63.0 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 1 N/A 0.086 in2.18 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.077 in1.96 mm N/A -55 to 200 ºC N/A 10.6 lb/1000 ft.15.71 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 1 N/A 0.086 in2.18 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.077 in1.96 mm N/A -55 to 200 ºC N/A 10.6 lb/1000 ft.15.71 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 2 N/A 0.147 in3.72 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.138 in3.51 mm N/A -55 to 200 ºC N/A 19.7 lb/1000 ft.29.40 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 2 N/A 0.147 in3.72 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.138 in3.51 mm N/A -55 to 200 ºC N/A 19.7 lb/1000 ft.29.40 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 3 N/A 0.156 in3.96 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.147 in3.74 mm N/A -55 to 200 ºC N/A 27.3 lb/1000 ft.40.60 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 3 N/A 0.156 in3.96 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.147 in3.74 mm N/A -55 to 200 ºC N/A 27.3 lb/1000 ft.40.60 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 4 N/A 0.172 in4.36 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.163 in4.14 mm N/A -55 to 200 ºC N/A 35.0 lb/1000 ft.52.10 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 4 N/A 0.172 in4.36 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.163 in4.14 mm N/A -55 to 200 ºC N/A 35.0 lb/1000 ft.52.10 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 1 N/A 0.076 in1.92 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.067 in1.70 mm N/A -55 to 200 ºC N/A 8.23 lb/1000 ft.12.25 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 1 N/A 0.076 in1.92 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.067 in1.70 mm N/A -55 to 200 ºC N/A 8.23 lb/1000 ft.12.25 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 2 N/A 0.127 in3.22 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.118 in3.00 mm N/A -55 to 200 ºC N/A 14.3 lb/1000 ft.21.30 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 2 N/A 0.127 in3.22 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.118 in3.00 mm N/A -55 to 200 ºC N/A 14.3 lb/1000 ft.21.30 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 3 N/A 0.134 in3.41 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.126 in3.19 mm N/A -55 to 200 ºC N/A 19.5 lb/1000 ft.29.00 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 3 N/A 0.134 in3.41 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.126 in3.19 mm N/A -55 to 200 ºC N/A 19.5 lb/1000 ft.29.00 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 4 N/A 0.148 in3.75 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.139 in3.53 mm N/A -55 to 200 ºC N/A 24.7 lb/1000 ft.36.80 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 4 N/A 0.148 in3.75 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.139 in3.53 mm N/A -55 to 200 ºC N/A 24.7 lb/1000 ft.36.80 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 1 N/A 0.068 in1.72 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.059 in1.50 mm N/A -55 to 200 ºC N/A 5.82 lb/1000 ft.8.65 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 1 N/A 0.068 in1.72 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.059 in1.50 mm N/A -55 to 200 ºC N/A 5.82 lb/1000 ft.8.65 kg/1000 m.