Leading provider
of high-performance wire,
cable and tubing since 1959
Toll Free:(800) 822-WIRE
Local: (661) 257-2400
Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/7 or /8 wires. These component wires have a light-weight insulation of two layers of FEP/polyimide/FEP tape with a polyimide hard coat for increased cut-through and abrasion resistance, and silver-or-nickel-plated copper conductors.
26 - 50 of 72 | Results Per Page | View | Unit of Measure
1 2 3 

Item #

Conductor Size

Stranding

Number of Wires

Jacket Diameter

Shield

Shield Diameter

Temperature Rating

Weight

Sort by
N/A 16 AWG N/A 19/29 N/A 2 N/A 0.159 in4.03 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.150 in3.81 mm N/A -55 to 200 ºC N/A 23.7 lb/1000 ft.35.30 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 2 N/A 0.147 in3.72 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.138 in3.51 mm N/A -55 to 200 ºC N/A 19.7 lb/1000 ft.29.40 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 2 N/A 0.147 in3.72 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.138 in3.51 mm N/A -55 to 200 ºC N/A 19.7 lb/1000 ft.29.40 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 2 N/A 0.127 in3.22 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.118 in3.00 mm N/A -55 to 200 ºC N/A 14.3 lb/1000 ft.21.30 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 2 N/A 0.127 in3.22 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.118 in3.00 mm N/A -55 to 200 ºC N/A 14.3 lb/1000 ft.21.30 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 2 N/A 0.111 in2.81 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.102 in2.59 mm N/A -55 to 200 ºC N/A 10.8 lb/1000 ft.16.1 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 2 N/A 0.111 in2.81 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.102 in2.59 mm N/A -55 to 200 ºC N/A 10.8 lb/1000 ft.16.1 kg/1000 m.
N/A 24 AWG N/A 19/36 N/A 2 N/A 0.097 in2.45 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.088 in2.24 mm N/A -55 to 200 ºC N/A 7.96 lb/1000 ft.11.8 kg/1000 m.
N/A 24 AWG N/A 19/36 N/A 2 N/A 0.097 in2.45 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.088 in2.24 mm N/A -55 to 200 ºC N/A 7.96 lb/1000 ft.11.8 kg/1000 m.
N/A 26 AWG N/A 19/38 N/A 2 N/A 0.091 in2.30 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.082 in2.08 mm N/A -55 to 200 ºC N/A 6.85 lb/1000 ft.10.20 kg/1000 m.
N/A 26 AWG N/A 19/38 N/A 2 N/A 0.091 in2.30 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.082 in2.08 mm N/A -55 to 200 ºC N/A 6.85 lb/1000 ft.10.20 kg/1000 m.
N/A 10 AWG N/A 37/26 N/A 3 N/A 0.291 in7.39 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.282 in7.17 mm N/A -55 to 200 ºC N/A 110.0 lb/1000 ft.164.00 kg/1000 m.
N/A 10 AWG N/A 37/26 N/A 3 N/A 0.291 in7.39 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.282 in7.17 mm N/A -55 to 200 ºC N/A 110.0 lb/1000 ft.164.00 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 3 N/A 0.237 in6.03 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.229 in5.81 mm N/A -55 to 200 ºC N/A 71.4 lb/1000 ft.106 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 3 N/A 0.237 in6.03 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.229 in5.81 mm N/A -55 to 200 ºC N/A 71.4 lb/1000 ft.106 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 3 N/A 0.197 in4.99 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.188 in4.78 mm N/A -55 to 200 ºC N/A 48.0 lb/1000 ft.71.50 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 3 N/A 0.197 in4.99 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.188 in4.78 mm N/A -55 to 200 ºC N/A 48.0 lb/1000 ft.71.50 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 3 N/A 0.169 in4.28 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.160 in4.07 mm N/A -55 to 200 ºC N/A 33.0 lb/1000 ft.49.1 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 3 N/A 0.169 in4.28 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.160 in4.07 mm N/A -55 to 200 ºC N/A 33.0 lb/1000 ft.49.1 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 3 N/A 0.156 in3.96 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.147 in3.74 mm N/A -55 to 200 ºC N/A 27.3 lb/1000 ft.40.60 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 3 N/A 0.156 in3.96 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.147 in3.74 mm N/A -55 to 200 ºC N/A 27.3 lb/1000 ft.40.60 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 3 N/A 0.134 in3.41 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.126 in3.19 mm N/A -55 to 200 ºC N/A 19.5 lb/1000 ft.29.00 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 3 N/A 0.134 in3.41 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.126 in3.19 mm N/A -55 to 200 ºC N/A 19.5 lb/1000 ft.29.00 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 3 N/A 0.117 in2.97 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.108 in2.75 mm N/A -55 to 200 ºC N/A 13.9 lb/1000 ft.20.7 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 3 N/A 0.117 in2.97 mm N/A Silver Plated Copper braid, 85% coverage N/A 0.108 in2.75 mm N/A -55 to 200 ºC N/A 13.9 lb/1000 ft.20.7 kg/1000 m.
26 - 50 of 72 | Results Per Page | View | Unit of Measure