Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/17 or /18 wires. These component wires have a light weight insulation of FEP/polyimide/FEP tape with an outer coating of modified aromatic polyimide. The component wires have silver- or nickel-plated copper conductors.
1 - 25 of 64 | Results Per Page | View | Unit of Measure
1 2 3 

Item #

Conductor Size

Stranding

Number of Wires

Jacket Diameter

Shield

Shield Diameter

Temperature Rating

Weight

Sort by
N/A 12 AWG N/A 37/28 N/A 1 N/A 0.121 in3.06 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.112 in2.84 mm N/A -55 to 200 ºC N/A 25.1 lb/1000 ft.37.30 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 2 N/A 0.217 in5.50 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.208 in5.28 mm N/A -55 to 200 ºC N/A 48.6 lb/1000 ft.72.40 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 3 N/A 0.231 in5.87 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.222 in5.65 mm N/A -55 to 200 ºC N/A 69.5 lb/1000 ft.103.00 kg/1000 m.
N/A 12 AWG N/A 37/28 N/A 4 N/A 0.260 in6.60 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.251 in6.38 mm N/A -55 to 200 ºC N/A 93.7 lb/1000 ft.139.00 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 1 N/A 0.102 in2.58 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.093 in2.36 mm N/A -55 to 200 ºC N/A 17.4 lb/1000 ft.26.0 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 2 N/A 0.179 in4.54 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.170 in4.32 mm N/A -55 to 200 ºC N/A 33.7 lb/1000 ft.50.2 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 3 N/A 0.190 in4.83 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.182 in4.61 mm N/A -55 to 200 ºC N/A 47.3 lb/1000 ft.70.40 kg/1000 m.
N/A 14 AWG N/A 19/27 N/A 4 N/A 0.210 in5.34 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.202 in5.12 mm N/A -55 to 200 ºC N/A 61.5 lb/1000 ft.91.50 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 1 N/A 0.089 in2.25 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.080 in2.03 mm N/A -55 to 200 ºC N/A 12.10 lb/1000 ft.18.00 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 2 N/A 0.153 in3.88 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.144 in3.66 mm N/A -55 to 200 ºC N/A 22.9 lb/1000 ft.34.1 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 3 N/A 0.162 in4.12 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.154 in3.90 mm N/A -55 to 200 ºC N/A 31.8 lb/1000 ft.47.40 kg/1000 m.
N/A 16 AWG N/A 19/29 N/A 4 N/A 0.179 in4.54 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.170 in4.32 mm N/A -55 to 200 ºC N/A 41.0 lb/1000 ft.61.0 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 1 N/A 0.082 in2.07 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.073 in1.85 mm N/A -55 to 200 ºC N/A 10.4 lb/1000 ft.15.5 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 2 N/A 0.139 in3.52 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.130 in3.30 mm N/A -55 to 200 ºC N/A 19.4 lb/1000 ft.28.90 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 3 N/A 0.147 in3.74 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.139 in3.52 mm N/A -55 to 200 ºC N/A 26.9 lb/1000 ft.40.00 kg/1000 m.
N/A 18 AWG N/A 19/30 N/A 4 N/A 0.162 in4.12 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.153 in3.90 mm N/A -55 to 200 ºC N/A 34.5 lb/1000 ft.51.3 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 1 N/A 0.073 in1.85 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.064 in1.63 mm N/A -55 to 200 ºC N/A 7.53 lb/1000 ft.11.2 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 2 N/A 0.121 in3.06 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.112 in2.84 mm N/A -55 to 200 ºC N/A 13.8 lb/1000 ft.20.60 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 3 N/A 0.128 in3.25 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.119 in3.03 mm N/A -55 to 200 ºC N/A 19.0 lb/1000 ft.28.20 kg/1000 m.
N/A 20 AWG N/A 19/32 N/A 4 N/A 0.140 in3.56 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.132 in3.34 mm N/A -55 to 200 ºC N/A 24.1 lb/1000 ft.35.9 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 1 N/A 0.065 in1.64 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.056 in1.42 mm N/A -55 to 200 ºC N/A 5.71 lb/1000 ft.8.49 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 2 N/A 0.105 in2.66 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.096 in2.44 mm N/A -55 to 200 ºC N/A 9.93 lb/1000 ft.14.80 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 3 N/A 0.111 in2.81 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.102 in2.59 mm N/A -55 to 200 ºC N/A 13.4 lb/1000 ft.19.9 kg/1000 m.
N/A 22 AWG N/A 19/34 N/A 4 N/A 0.121 in3.07 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.112 in2.85 mm N/A -55 to 200 ºC N/A 16.9 lb/1000 ft.25.2 kg/1000 m.
N/A 24 AWG N/A 19/36 N/A 1 N/A 0.059 in1.49 mm N/A Nickel Plated Copper braid, 85% coverage N/A 0.050 in1.27 mm N/A -55 to 200 ºC N/A 4.79 lb/1000 ft.7.12 kg/1000 m.