MIL-W-16878/5 (Type EE) Wire, Heavy-wall Extruded PTFE Insulation
MIL-W-16878 (NEMA HP3, HP4) MIL/Aero Wire
MIL-W-16878/5 (type EE) wires have extruded PTFE insulation (heavy wall thickness) for high- temperature applications. PTFE insulation offers high reliability with excellent thermal stability and chemical resistance.
Item # |
Conductor |
Conductor Size |
Conductor Diameter |
Stranding |
Min. Insulation Diameter |
Max. Resistance per 1000 ft. @ 20°C |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
W221-16 | Conductor N/A Silver-Plated Copper | Conductor Size N/A 16 AWG | Conductor Diameter N/A 0.053 in1.350 mm | Stranding N/A 19/29 | Min. Insulation Diameter N/A 0.083 in2.11 mm | Max. Resistance per 1000 ft. @ 20°C N/A 4.52 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.1 lb/1000 ft.16.50 kg/1000 m. |
W221-16HSCA | Conductor N/A Silver-Plated High-Strength Copper | Conductor Size N/A 16 AWG | Conductor Diameter N/A 0.053 in1.350 mm | Stranding N/A 19/29 | Min. Insulation Diameter N/A 0.083 in2.11 mm | Max. Resistance per 1000 ft. @ 20°C N/A 4.52 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.1 lb/1000 ft.16.50 kg/1000 m. |
W221-16NIC | Conductor N/A Nickel-Plated Copper | Conductor Size N/A 16 AWG | Conductor Diameter N/A 0.053 in1.350 mm | Stranding N/A 19/29 | Min. Insulation Diameter N/A 0.083 in2.11 mm | Max. Resistance per 1000 ft. @ 20°C N/A 4.52 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 11.1 lb/1000 ft.16.50 kg/1000 m. |
W221-16NHSCA | Conductor N/A Nickel-Plated High-Strength Copper | Conductor Size N/A 16 AWG | Conductor Diameter N/A 0.053 in1.350 mm | Stranding N/A 19/29 | Min. Insulation Diameter N/A 0.083 in2.11 mm | Max. Resistance per 1000 ft. @ 20°C N/A 4.52 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 11.1 lb/1000 ft.16.50 kg/1000 m. |
W221-14 | Conductor N/A Silver-Plated Copper | Conductor Size N/A 14 AWG | Conductor Diameter N/A 0.067 in1.700 mm | Stranding N/A 19/27 | Min. Insulation Diameter N/A 0.098 in2.49 mm | Max. Resistance per 1000 ft. @ 20°C N/A 2.88 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 16.4 lb/1000 ft.24.4 kg/1000 m. |
W221-14HSCA | Conductor N/A Silver-Plated High-Strength Copper | Conductor Size N/A 14 AWG | Conductor Diameter N/A 0.067 in1.700 mm | Stranding N/A 19/27 | Min. Insulation Diameter N/A 0.098 in2.49 mm | Max. Resistance per 1000 ft. @ 20°C N/A 2.88 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 16.4 lb/1000 ft.24.4 kg/1000 m. |
W221-14NIC | Conductor N/A Nickel-Plated Copper | Conductor Size N/A 14 AWG | Conductor Diameter N/A 0.067 in1.700 mm | Stranding N/A 19/27 | Min. Insulation Diameter N/A 0.098 in2.49 mm | Max. Resistance per 1000 ft. @ 20°C N/A 2.88 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 16.4 lb/1000 ft.24.4 kg/1000 m. |
W221-14NHSCA | Conductor N/A Nickel-Plated High-Strength Copper | Conductor Size N/A 14 AWG | Conductor Diameter N/A 0.067 in1.700 mm | Stranding N/A 19/27 | Min. Insulation Diameter N/A 0.098 in2.49 mm | Max. Resistance per 1000 ft. @ 20°C N/A 2.88 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 16.4 lb/1000 ft.24.4 kg/1000 m. |
W221-12 | Conductor N/A Silver-Plated Copper | Conductor Size N/A 12 AWG | Conductor Diameter N/A 0.084 in2.130 mm | Stranding N/A 19/25 | Min. Insulation Diameter N/A 0.117 in2.97 mm | Max. Resistance per 1000 ft. @ 20°C N/A 1.81 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.8 lb/1000 ft.36.9 kg/1000 m. |
W221-12HSCA | Conductor N/A Silver-Plated High-Strength Copper | Conductor Size N/A 12 AWG | Conductor Diameter N/A 0.084 in2.130 mm | Stranding N/A 19/25 | Min. Insulation Diameter N/A 0.117 in2.97 mm | Max. Resistance per 1000 ft. @ 20°C N/A 1.81 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.8 lb/1000 ft.36.9 kg/1000 m. |
W221-12NIC | Conductor N/A Nickel-Plated Copper | Conductor Size N/A 12 AWG | Conductor Diameter N/A 0.084 in2.130 mm | Stranding N/A 19/25 | Min. Insulation Diameter N/A 0.117 in2.97 mm | Max. Resistance per 1000 ft. @ 20°C N/A 1.81 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 24.8 lb/1000 ft.36.9 kg/1000 m. |
W221-12NHSCA | Conductor N/A Nickel-Plated High-Strength Copper | Conductor Size N/A 12 AWG | Conductor Diameter N/A 0.084 in2.130 mm | Stranding N/A 19/25 | Min. Insulation Diameter N/A 0.117 in2.97 mm | Max. Resistance per 1000 ft. @ 20°C N/A 1.81 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 24.8 lb/1000 ft.36.9 kg/1000 m. |
W221-10 | Conductor N/A Silver-Plated Copper | Conductor Size N/A 10 AWG | Conductor Diameter N/A 0.108 in2.740 mm | Stranding N/A 37/26 | Min. Insulation Diameter N/A 0.137 in3.48 mm | Max. Resistance per 1000 ft. @ 20°C N/A 1.19 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 35.3 lb/1000 ft.52.50 kg/1000 m. |
W221-10HCCA | Conductor N/A Silver-Plated High-Strength Copper | Conductor Size N/A 10 AWG | Conductor Diameter N/A 0.108 in2.740 mm | Stranding N/A 37/26 | Min. Insulation Diameter N/A 0.137 in3.48 mm | Max. Resistance per 1000 ft. @ 20°C N/A 1.81 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 35.3 lb/1000 ft.36.9 kg/1000 m. |
2221-10NIC | Conductor N/A Nickel-Plated Copper | Conductor Size N/A 10 AWG | Conductor Diameter N/A 0.108 in2.740 mm | Stranding N/A 37/26 | Min. Insulation Diameter N/A 0.137 in3.48 mm | Max. Resistance per 1000 ft. @ 20°C N/A 1.19 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 35.3 lb/1000 ft.36.9 kg/1000 m. |
W221-10NHSCA | Conductor N/A Nickel-Plated High-Strength Copper | Conductor Size N/A 10 AWG | Conductor Diameter N/A 0.108 in2.740 mm | Stranding N/A 37/26 | Min. Insulation Diameter N/A 0.137 in3.48 mm | Max. Resistance per 1000 ft. @ 20°C N/A 1.19 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 35.3 lb/1000 ft.36.9 kg/1000 m. |
W221-8 | Conductor N/A Silver-Plated Copper | Conductor Size N/A 8 AWG | Conductor Diameter N/A 0.162 in4.110 mm | Stranding N/A 133/29 | Min. Insulation Diameter N/A 0.199 in5.05 mm | Max. Resistance per 1000 ft. @ 20°C N/A 0.658 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 65.9 lb/1000 ft.98.10 kg/1000 m. |
W221-8HSCA | Conductor N/A Silver-Plated High-Strength Copper | Conductor Size N/A 8 AWG | Conductor Diameter N/A 0.162 in4.110 mm | Stranding N/A 133/29 | Min. Insulation Diameter N/A 0.199 in5.05 mm | Max. Resistance per 1000 ft. @ 20°C N/A 0.658 ohms | Temperature Rating N/A -55 to 200 ºC | Weight N/A 65.9 lb/1000 ft.98.10 kg/1000 m. |
W221-8NIC | Conductor N/A Nickel-Plated Copper | Conductor Size N/A 8 AWG | Conductor Diameter N/A 0.162 in4.110 mm | Stranding N/A 133/29 | Min. Insulation Diameter N/A 0.199 in5.05 mm | Max. Resistance per 1000 ft. @ 20°C N/A 0.658 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 65.9 lb/1000 ft.98.10 kg/1000 m. |
W221-8NHSCA | Conductor N/A Nickel-Plated High-Strength Copper | Conductor Size N/A 8 AWG | Conductor Diameter N/A 0.162 in4.110 mm | Stranding N/A 133/29 | Min. Insulation Diameter N/A 0.199 in5.05 mm | Max. Resistance per 1000 ft. @ 20°C N/A 0.658 ohms | Temperature Rating N/A -55 to 260 ºC | Weight N/A 65.9 lb/1000 ft.98.10 kg/1000 m. |