M27500 Cable-Types MS (M81381/8 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/7 or /8 wires. These component wires have a light-weight insulation of two layers of FEP/polyimide/FEP tape with a polyimide hard coat for increased cut-through and abrasion resistance, and silver-or-nickel-plated copper conductors.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-26 MS 4 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.104 in2.65 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.5 lb/1000 ft.15.70 kg/1000 m. |
M27500-26 MS 4 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.104 in2.65 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.5 lb/1000 ft.15.70 kg/1000 m. |
M27500-26 MS 3 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 3 | Jacket Diameter N/A 0.096 in2.43 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.087 in2.21 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.41 lb/1000 ft.12.5 kg/1000 m. |
M27500-26 MS 3 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 3 | Jacket Diameter N/A 0.096 in2.43 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.087 in2.21 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.41 lb/1000 ft.12.5 kg/1000 m. |
M27500-26 MS 2 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 2 | Jacket Diameter N/A 0.091 in2.30 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.082 in2.08 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.85 lb/1000 ft.10.20 kg/1000 m. |
M27500-26 MS 2 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 2 | Jacket Diameter N/A 0.091 in2.30 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.082 in2.08 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.85 lb/1000 ft.10.20 kg/1000 m. |
M27500-26 MS 1 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.058 in1.46 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.049 in1.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.31 lb/1000 ft.6.41 kg/1000 m. |
M27500-26 MS 1 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.058 in1.46 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.049 in1.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.31 lb/1000 ft.6.41 kg/1000 m. |
M27500-24 MS 4 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.62 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.8 lb/1000 ft.19.0 kg/1000 m. |
M27500-24 MS 4 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.62 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.8 lb/1000 ft.19.0 kg/1000 m. |
M27500-24 MS 3 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 3 | Jacket Diameter N/A 0.102 in2.59 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.093 in2.37 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.7 lb/1000 ft.15.9 kg/1000 m. |
M27500-24 MS 3 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 3 | Jacket Diameter N/A 0.102 in2.59 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.093 in2.37 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.7 lb/1000 ft.15.9 kg/1000 m. |
M27500-24 MS 2 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 2 | Jacket Diameter N/A 0.097 in2.45 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.088 in2.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 7.96 lb/1000 ft.11.8 kg/1000 m. |
M27500-24 MS 2 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 2 | Jacket Diameter N/A 0.097 in2.45 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.088 in2.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 7.96 lb/1000 ft.11.8 kg/1000 m. |
M27500-24 MS 1 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.061 in1.54 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.052 in1.32 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.84 lb/1000 ft.7.20 kg/1000 m. |
M27500-24 MS 1 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.061 in1.54 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.052 in1.32 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.84 lb/1000 ft.7.20 kg/1000 m. |
M27500-22 MS 4 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.128 in3.26 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.120 in3.05 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-22 MS 4 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.128 in3.26 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.120 in3.05 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-22 MS 3 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.117 in2.97 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.108 in2.75 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.9 lb/1000 ft.20.7 kg/1000 m. |
M27500-22 MS 3 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.117 in2.97 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.108 in2.75 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.9 lb/1000 ft.20.7 kg/1000 m. |
M27500-22 MS 2 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.111 in2.81 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.102 in2.59 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.8 lb/1000 ft.16.1 kg/1000 m. |
M27500-22 MS 2 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.111 in2.81 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.102 in2.59 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.8 lb/1000 ft.16.1 kg/1000 m. |
M27500-22 MS 1 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.068 in1.72 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.059 in1.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.82 lb/1000 ft.8.65 kg/1000 m. |
M27500-22 MS 1 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.068 in1.72 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.059 in1.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.82 lb/1000 ft.8.65 kg/1000 m. |
M27500-20 MS 4 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.148 in3.75 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.139 in3.53 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.7 lb/1000 ft.36.80 kg/1000 m. |