M27500 Cable-Types MS (M81381/8 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape, incorporating MIL-DTL-81381/7 or /8 wires. These component wires have a light-weight insulation of two layers of FEP/polyimide/FEP tape with a polyimide hard coat for increased cut-through and abrasion resistance, and silver-or-nickel-plated copper conductors.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-16 MS 2 N 12 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 2 | Jacket Diameter N/A 0.159 in4.03 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.150 in3.81 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 23.7 lb/1000 ft.35.30 kg/1000 m. |
M27500-18 MS 3 S 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 3 | Jacket Diameter N/A 0.156 in3.96 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.147 in3.74 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 27.3 lb/1000 ft.40.60 kg/1000 m. |
M27500-18 MS 3 N 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 3 | Jacket Diameter N/A 0.156 in3.96 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.147 in3.74 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 27.3 lb/1000 ft.40.60 kg/1000 m. |
M27500-20 MS 4 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.148 in3.75 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.139 in3.53 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.7 lb/1000 ft.36.80 kg/1000 m. |
M27500-20 MS 4 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.148 in3.75 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.139 in3.53 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.7 lb/1000 ft.36.80 kg/1000 m. |
M27500-18 MS 2 S 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 2 | Jacket Diameter N/A 0.147 in3.72 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.138 in3.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 19.7 lb/1000 ft.29.40 kg/1000 m. |
M27500-18 MS 2 N 12 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 2 | Jacket Diameter N/A 0.147 in3.72 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.138 in3.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 19.7 lb/1000 ft.29.40 kg/1000 m. |
M27500-10 MS 1 S 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.147 in3.72 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.138 in3.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 37.9 lb/1000 ft.56.46 kg/1000 m. |
M27500-10 MS 1 N 12 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.147 in3.72 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.138 in3.51 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 37.9 lb/1000 ft.56.46 kg/1000 m. |
M27500-20 MS 3 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 3 | Jacket Diameter N/A 0.134 in3.41 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.126 in3.19 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 19.5 lb/1000 ft.29.00 kg/1000 m. |
M27500-20 MS 3 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 3 | Jacket Diameter N/A 0.134 in3.41 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.126 in3.19 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 19.5 lb/1000 ft.29.00 kg/1000 m. |
M27500-22 MS 4 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.128 in3.26 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.120 in3.05 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-22 MS 4 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.128 in3.26 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.120 in3.05 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-20 MS 2 S 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 2 | Jacket Diameter N/A 0.127 in3.22 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.118 in3.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.3 lb/1000 ft.21.30 kg/1000 m. |
M27500-20 MS 2 N 12 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 2 | Jacket Diameter N/A 0.127 in3.22 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.118 in3.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.3 lb/1000 ft.21.30 kg/1000 m. |
M27500-12 MS 1 S 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.124 in3.14 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.115 in2.92 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.7 lb/1000 ft.38.19 kg/1000 m. |
M27500-12 MS 1 N 12 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.124 in3.14 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.115 in2.92 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.7 lb/1000 ft.38.19 kg/1000 m. |
M27500-22 MS 3 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.117 in2.97 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.108 in2.75 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.9 lb/1000 ft.20.7 kg/1000 m. |
M27500-22 MS 3 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.117 in2.97 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.108 in2.75 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.9 lb/1000 ft.20.7 kg/1000 m. |
M27500-24 MS 4 S 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.62 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.8 lb/1000 ft.19.0 kg/1000 m. |
M27500-24 MS 4 N 12 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.62 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 12.8 lb/1000 ft.19.0 kg/1000 m. |
M27500-22 MS 2 S 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.111 in2.81 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.102 in2.59 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.8 lb/1000 ft.16.1 kg/1000 m. |
M27500-22 MS 2 N 12 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.111 in2.81 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.102 in2.59 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.8 lb/1000 ft.16.1 kg/1000 m. |
M27500-26 MS 4 S 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.104 in2.65 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.5 lb/1000 ft.15.70 kg/1000 m. |
M27500-26 MS 4 N 12 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.104 in2.65 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.096 in2.44 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.5 lb/1000 ft.15.70 kg/1000 m. |