M27500 Cable-Types WK (M22759/87 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape covered by a PTFE tape outer layer, incorporating MIL-DTL-22759/86, /87, /88 wires. These component wires have a light-weight composite insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape and silver, nickel, or tin-plated copper conductors.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-22 WK 2 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.109 in2.76 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.100 in2.54 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.8 lb/1000 ft.16.1 kg/1000 m. |
M27500-24 WK 4 N 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.1 lb/1000 ft.19.40 kg/1000 m. |
M27500-24 WK 4 S 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.1 lb/1000 ft.19.40 kg/1000 m. |
M27500-22 WK 3 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.115 in2.92 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.106 in2.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.5 lb/1000 ft.21.50 kg/1000 m. |
M27500-22 WK 3 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.115 in2.92 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.106 in2.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.5 lb/1000 ft.21.50 kg/1000 m. |
M27500-12 WK 1 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.123 in3.12 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.114 in2.90 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 26.3 lb/1000 ft.39.00 kg/1000 m. |
M27500-12 WK 1 S 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.123 in3.12 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.114 in2.90 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 26.3 lb/1000 ft.39.00 kg/1000 m. |
M27500-20 WK 2 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 2 | Jacket Diameter N/A 0.125 in3.17 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.116 in2.95 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.8 lb/1000 ft.22.10 kg/1000 m. |
M27500-20 WK 2 S 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 2 | Jacket Diameter N/A 0.125 in3.17 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.116 in2.95 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.8 lb/1000 ft.22.10 kg/1000 m. |
M27500-22 WK 4 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.126 in3.20 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in3.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-22 WK 4 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.126 in3.20 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in3.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-20 WK 3 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 3 | Jacket Diameter N/A 0.132 in3.36 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.124 in3.14 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 20.1 lb/1000 ft.30.0 kg/1000 m. |
M27500-20 WK 3 S 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 3 | Jacket Diameter N/A 0.132 in3.36 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.124 in3.14 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 20.1 lb/1000 ft.30.0 kg/1000 m. |
M27500-18 WK 2 N 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 2 | Jacket Diameter N/A 0.141 in3.57 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.132 in3.35 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 20.3 lb/1000 ft.30.1 kg/1000 m. |
M27500-18 WK 2 S 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 2 | Jacket Diameter N/A 0.141 in3.57 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.132 in3.35 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 20.3 lb/1000 ft.30.1 kg/1000 m. |
M27500-10 WK 1 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.146 in3.70 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.48 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 48.4 lb/1000 ft.57.10 kg/1000 m. |
M27500-10 WK 1 S 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.146 in3.70 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.48 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 48.4 lb/1000 ft.57.10 kg/1000 m. |
M27500-20 WK 4 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.145 in3.69 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.6 lb/1000 ft.38.00 kg/1000 m. |
M27500-20 WK 4 S 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 4 | Jacket Diameter N/A 0.145 in3.69 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.50 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 25.6 lb/1000 ft.38.00 kg/1000 m. |
M27500-18 WK 3 N 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 3 | Jacket Diameter N/A 0.149 in3.79 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.141 in3.57 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 27.9 lb/1000 ft.41.60 kg/1000 m. |
M27500-18 WK 3 S 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 3 | Jacket Diameter N/A 0.149 in3.79 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.141 in3.57 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 27.9 lb/1000 ft.41.60 kg/1000 m. |
M27500-16 WK 2 N 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 2 | Jacket Diameter N/A 0.155 in3.93 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.146 in3.71 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.3 lb/1000 ft.36.10 kg/1000 m. |
M27500-16 WK 2 S 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 2 | Jacket Diameter N/A 0.155 in3.93 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.146 in3.71 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.3 lb/1000 ft.36.10 kg/1000 m. |
M27500-16 WK 3 N 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 3 | Jacket Diameter N/A 0.164 in4.18 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.156 in3.96 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 33.9 lb/1000 ft.50.40 kg/1000 m. |
M27500-16 WK 3 S 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 3 | Jacket Diameter N/A 0.164 in4.18 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.156 in3.96 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 33.9 lb/1000 ft.50.40 kg/1000 m. |