M27500 Cable-Types WL (M22759/88 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape covered by a PTFE tape outer layer, incorporating MIL-DTL-22759/86, /87, /88 wires. These component wires have a light-weight composite insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape and silver, nickel, or tin-plated copper conductors.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-10 WL 1 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.146 in3.70 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.48 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 48.4 lb/1000 ft.57.10 kg/1000 m. |
M27500-10 WL 1 S 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.146 in3.70 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.48 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 48.4 lb/1000 ft.57.10 kg/1000 m. |
M27500-12 WL 1 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.123 in3.12 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.114 in2.90 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 26.3 lb/1000 ft.39.00 kg/1000 m. |
M27500-12 WL 1 S 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.123 in3.12 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.114 in2.90 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 26.3 lb/1000 ft.39.00 kg/1000 m. |
M27500-14 WL 1 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 1 | Jacket Diameter N/A 0.103 in2.61 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.094 in2.39 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18 lb/1000 ft.26.80 kg/1000 m. |
M27500-14 WL 1 S 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 1 | Jacket Diameter N/A 0.103 in2.61 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.094 in2.39 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18 lb/1000 ft.26.80 kg/1000 m. |
M27500-16 WL 1 N 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 1 | Jacket Diameter N/A 0.090 in2.28 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.081 in2.06 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.0 lb/1000 ft.19.40 kg/1000 m. |
M27500-16 WL 1 S 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 1 | Jacket Diameter N/A 0.090 in2.28 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.081 in2.06 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.0 lb/1000 ft.19.40 kg/1000 m. |
M27500-18 WL 1 N 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 1 | Jacket Diameter N/A 0.083 in2.10 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.074 in1.88 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.1 lb/1000 ft.16.50 kg/1000 m. |
M27500-18 WL 1 S 24 | Conductor Size N/A 18 AWG | Stranding N/A 19/30 | Number of Wires N/A 1 | Jacket Diameter N/A 0.083 in2.10 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.074 in1.88 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 11.1 lb/1000 ft.16.50 kg/1000 m. |
M27500-20 WL 1 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.075 in1.90 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.066 in1.68 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.17 lb/1000 ft.12.2 kg/1000 m. |
M27500-20 WL 1 S 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.075 in1.90 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.066 in1.68 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.17 lb/1000 ft.12.2 kg/1000 m. |
M27500-22 WL 1 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.067 in1.69 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.058 in1.47 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.17 lb/1000 ft.9.18 kg/1000 m. |
M27500-22 WL 1 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.067 in1.69 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.058 in1.47 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.17 lb/1000 ft.9.18 kg/1000 m. |
M27500-24 WL 1 N 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.061 in1.54 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.052 in1.32 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.07 lb/1000 ft.7.54 kg/1000 m. |
M27500-24 WL 1 S 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.061 in1.54 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.052 in1.32 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.07 lb/1000 ft.7.54 kg/1000 m. |
M27500-26 WL 1 N 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.057 in1.44 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.048 in1.22 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.62 lb/1000 ft.6.88 kg/1000 m. |
M27500-26 WL 1 S 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.057 in1.44 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.048 in1.22 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.62 lb/1000 ft.6.88 kg/1000 m. |
M27500-10 WL 2 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 2 | Jacket Diameter N/A 0.271 in6.87 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.262 in6.65 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 74.7 lb/1000 ft.111.00 kg/1000 m. |
M27500-10 WL 2 S 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 2 | Jacket Diameter N/A 0.271 in6.87 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.262 in6.65 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 74.7 lb/1000 ft.111.00 kg/1000 m. |
M27500-12 WL 2 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 2 | Jacket Diameter N/A 0.221 in5.60 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.212 in5.38 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 50.2 lb/1000 ft.74.70 kg/1000 m. |
M27500-12 WL 2 S 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 2 | Jacket Diameter N/A 0.221 in5.60 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.212 in5.38 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 50.2 lb/1000 ft.74.70 kg/1000 m. |
M27500-14 WL 2 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 2 | Jacket Diameter N/A 0.181 in4.59 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.172 in4.37 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 34.2 lb/1000 ft.50.90 kg/1000 m. |
M27500-14 WL 2 S 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 2 | Jacket Diameter N/A 0.181 in4.59 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.172 in4.37 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 34.2 lb/1000 ft.50.90 kg/1000 m. |
M27500-16 WL 2 N 24 | Conductor Size N/A 16 AWG | Stranding N/A 19/29 | Number of Wires N/A 2 | Jacket Diameter N/A 0.155 in3.93 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.146 in3.71 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 24.3 lb/1000 ft.36.10 kg/1000 m. |