M27500 Cable-Types WN (M22759/90 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape covered by a PTFE tape outer layer, incorporating MIL-DTL-22759/89 or /90 wires. These component wires have a light-weight composite insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape and silver-or-nickel plated high-strength copper alloy conductors.
1 2
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-26 WN 1 N 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.057 in1.44 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.048 in1.22 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.62 lb/1000 ft.6.88 kg/1000 m. |
M27500-26 WN 1 S 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 1 | Jacket Diameter N/A 0.057 in1.44 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.048 in1.22 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 4.62 lb/1000 ft.6.88 kg/1000 m. |
M27500-26 WN 2 N 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 2 | Jacket Diameter N/A 0.089 in2.25 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.080 in2.03 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.67 lb/1000 ft.9.93 kg/1000 m. |
M27500-26 WN 2 S 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 2 | Jacket Diameter N/A 0.089 in2.25 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.080 in2.03 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.67 lb/1000 ft.9.93 kg/1000 m. |
M27500-26 WN 3 N 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 3 | Jacket Diameter N/A 0.093 in2.37 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.085 in2.15 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.76 lb/1000 ft.13.0 kg/1000 m. |
M27500-26 WN 3 S 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 3 | Jacket Diameter N/A 0.093 in2.37 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.085 in2.15 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.76 lb/1000 ft.13.0 kg/1000 m. |
M27500-26 WN 4 N 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.102 in2.58 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.093 in2.40 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.6 lb/1000 ft.15.70 kg/1000 m. |
M27500-26 WN 4 S 24 | Conductor Size N/A 26 AWG | Stranding N/A 19/38 | Number of Wires N/A 4 | Jacket Diameter N/A 0.102 in2.58 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.093 in2.40 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.6 lb/1000 ft.15.70 kg/1000 m. |
M27500-24 WN 1 N 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.061 in1.54 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.052 in1.32 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.07 lb/1000 ft.7.54 kg/1000 m. |
M27500-24 WN 1 S 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 1 | Jacket Diameter N/A 0.061 in1.54 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.052 in1.32 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 5.07 lb/1000 ft.7.54 kg/1000 m. |
M27500-24 WN 2 N 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 2 | Jacket Diameter N/A 0.097 in2.45 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.088 in2.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.24 lb/1000 ft.12.30 kg/1000 m. |
M27500-24 WN 2 S 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 2 | Jacket Diameter N/A 0.097 in2.45 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.088 in2.24 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.24 lb/1000 ft.12.30 kg/1000 m. |
M27500-24 WN 3 N 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 3 | Jacket Diameter N/A 0.102 in2.59 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.093 in2.37 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.5 lb/1000 ft.15.6 kg/1000 m. |
M27500-24 WN 3 S 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 3 | Jacket Diameter N/A 0.102 in2.59 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.093 in2.37 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.5 lb/1000 ft.15.6 kg/1000 m. |
M27500-24 WN 4 N 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.1 lb/1000 ft.19.40 kg/1000 m. |
M27500-24 WN 4 S 24 | Conductor Size N/A 24 AWG | Stranding N/A 19/36 | Number of Wires N/A 4 | Jacket Diameter N/A 0.111 in2.83 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.103 in2.60 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 13.1 lb/1000 ft.19.40 kg/1000 m. |
M27500-22 WN 1 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.067 in1.69 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.058 in1.47 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.17 lb/1000 ft.9.18 kg/1000 m. |
M27500-22 WN 1 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 1 | Jacket Diameter N/A 0.067 in1.69 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.058 in1.47 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 6.17 lb/1000 ft.9.18 kg/1000 m. |
M27500-22 WN 2 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.109 in2.76 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.100 in2.54 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.8 lb/1000 ft.16.1 kg/1000 m. |
M27500-22 WN 2 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 2 | Jacket Diameter N/A 0.109 in2.76 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.100 in2.54 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 10.8 lb/1000 ft.16.1 kg/1000 m. |
M27500-22 WN 3 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.115 in2.92 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.106 in2.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.5 lb/1000 ft.21.50 kg/1000 m. |
M27500-22 WN 3 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 3 | Jacket Diameter N/A 0.115 in2.92 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.106 in2.70 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 14.5 lb/1000 ft.21.50 kg/1000 m. |
M27500-22 WN 4 N 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.126 in3.20 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in3.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-22 WN 4 S 24 | Conductor Size N/A 22 AWG | Stranding N/A 19/34 | Number of Wires N/A 4 | Jacket Diameter N/A 0.126 in3.20 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.117 in3.00 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 18.1 lb/1000 ft.27.00 kg/1000 m. |
M27500-20 WN 1 N 24 | Conductor Size N/A 20 AWG | Stranding N/A 19/32 | Number of Wires N/A 1 | Jacket Diameter N/A 0.075 in1.90 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.066 in1.68 mm | Temperature Rating N/A -55 to 200 ºC | Weight N/A 8.17 lb/1000 ft.12.2 kg/1000 m. |
1 2