M27500 Cable-Types WR (M22759/92 Components)
MIL-DTL-27500 (NEMA WC27500) MIL/Aero Cables
Shielded and jacketed cables with a jacket of FEP/polyimide tape covered by a PTFE tape outer layer, incorporating AS22759/92 wires. These component wires have a light-weight composite insulation of PTFE/polyimide/PTFE tape, covered with PTFE tape and nickel plated copper conductor.
Item # |
Conductor Size |
Stranding |
Number of Wires |
Jacket Diameter |
Shield |
Shield Diameter |
Temperature Rating |
Weight |
---|---|---|---|---|---|---|---|---|
M27500-14 WR 3 S 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 3 | Jacket Diameter N/A 0.192 in4.89 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.184 in4.67 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 47.9 lb/1000 ft.71.30 kg/1000 m. |
M27500-14 WR 3 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 3 | Jacket Diameter N/A 0.192 in4.89 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.184 in4.67 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 47.9 lb/1000 ft.71.30 kg/1000 m. |
M27500-14 WR 2 S 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 2 | Jacket Diameter N/A 0.181 in4.59 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.172 in4.37 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 34.2 lb/1000 ft.50.90 kg/1000 m. |
M27500-14 WR 2 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 2 | Jacket Diameter N/A 0.181 in4.59 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.172 in4.37 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 34.2 lb/1000 ft.50.90 kg/1000 m. |
M27500-14 WR 1 S 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 1 | Jacket Diameter N/A 0.103 in2.61 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.094 in2.39 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 18 lb/1000 ft.26.80 kg/1000 m. |
M27500-14 WR 1 N 24 | Conductor Size N/A 14 AWG | Stranding N/A 19/27 | Number of Wires N/A 1 | Jacket Diameter N/A 0.103 in2.61 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.094 in2.39 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 18 lb/1000 ft.26.80 kg/1000 m. |
M27500-12 WR 4 S 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 4 | Jacket Diameter N/A 0.265 in6.73 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.256 in6.50 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 93.1 lb/1000 ft.138.00 kg/1000 m. |
M27500-12 WR 4 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 4 | Jacket Diameter N/A 0.265 in6.73 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.256 in6.50 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 93.1 lb/1000 ft.138.00 kg/1000 m. |
M27500-12 WR 3 S 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 3 | Jacket Diameter N/A 0.235 in5.98 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.227 in5.76 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 71.4 lb/1000 ft.106 kg/1000 m. |
M27500-12 WR 3 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 3 | Jacket Diameter N/A 0.235 in5.98 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.227 in5.76 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 71.4 lb/1000 ft.106 kg/1000 m. |
M27500-12 WR 2 S 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 2 | Jacket Diameter N/A 0.221 in5.60 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.212 in5.38 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 50.2 lb/1000 ft.74.70 kg/1000 m. |
M27500-12 WR 2 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 2 | Jacket Diameter N/A 0.221 in5.60 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.212 in5.38 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 50.2 lb/1000 ft.74.70 kg/1000 m. |
M27500-12 WR 1 S 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.123 in3.12 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.114 in2.90 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 26.3 lb/1000 ft.39.00 kg/1000 m. |
M27500-12 WR 1 N 24 | Conductor Size N/A 12 AWG | Stranding N/A 37/28 | Number of Wires N/A 1 | Jacket Diameter N/A 0.123 in3.12 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.114 in2.90 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 26.3 lb/1000 ft.39.00 kg/1000 m. |
M27500-10 WR 4 S 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 4 | Jacket Diameter N/A 0.324 in8.23 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.312 in7.90 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 143.0 lb/1000 ft.213.00 kg/1000 m. |
M27500-10 WR 4 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 4 | Jacket Diameter N/A 0.324 in8.23 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.312 in7.90 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 143.0 lb/1000 ft.213.00 kg/1000 m. |
M27500-10 WR 3 S 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 3 | Jacket Diameter N/A 0.289 in7.34 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.280 in7.12 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 110.0 lb/1000 ft.164.00 kg/1000 m. |
M27500-10 WR 3 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 3 | Jacket Diameter N/A 0.289 in7.34 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.280 in7.12 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 110.0 lb/1000 ft.164.00 kg/1000 m. |
M27500-10 WR 2 S 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 2 | Jacket Diameter N/A 0.271 in6.87 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.262 in6.65 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 74.7 lb/1000 ft.111.00 kg/1000 m. |
M27500-10 WR 2 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 2 | Jacket Diameter N/A 0.271 in6.87 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.262 in6.65 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 74.7 lb/1000 ft.111.00 kg/1000 m. |
M27500-10 WR 1 S 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.146 in3.70 mm | Shield N/A Silver Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.48 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 48.4 lb/1000 ft.57.10 kg/1000 m. |
M27500-10 WR 1 N 24 | Conductor Size N/A 10 AWG | Stranding N/A 37/26 | Number of Wires N/A 1 | Jacket Diameter N/A 0.146 in3.70 mm | Shield N/A Nickel Plated Copper braid, 85% coverage | Shield Diameter N/A 0.137 in3.48 mm | Temperature Rating N/A -55 to 260 ºC | Weight N/A 48.4 lb/1000 ft.57.10 kg/1000 m. |