M22759 (SAE-AS22759) MIL/Aero Wire & Cables
mil-m22759-sae-as22759-mil-aero-wire-cables
150°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
200°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
150°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
200°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
200°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
200°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
200°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
200°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
200°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
200°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
M22759/5 Wire - Mineral-filled PTFE Insulation
(8) M22759/5 wires have mineral-filled PTFE insulation for high-temperature applications such as aircraft engines, SWAMP zones, and others where increased abrasion resistance is required. For reduced-weight versions of these wires, see M22759/7 and /8 0000083295_008.jpgM22759/6 Wire - Mineral-filled PTFE Insulation
(9) M22759/6 wires have mineral-filled PTFE insulation for high-temperature applications such as aircraft engines, SWAMP zones, and others where increased abrasion resistance is required. For reduced-weight versions of these wires, see M22759/7 and /8 0000083295_008.jpgM22759/7 Wire - Mineral-filled PTFE Insulation - Medium Wall
(9) M22759/7 wires have reduced weight, mineral-filled PTFE insulation for high-temperature applications such as aircraft engines, SWAMP zones, and others where increased abrasion resistance is required.These wires are reduced-weight versions of M22759/5 and /6. 0000083295_008.jpgM22759/8 Wire - Mineral-filled PTFE Insulation - Medium Wall
(9) M22759/8 wires have reduced weight, mineral-filled PTFE insulation for high-temperature applications such as aircraft engines, SWAMP zones, and others where increased abrasion resistance is required.These wires are reduced-weight versions of M22759/5 and /6. 0000083295_008.jpgM22759/9 Wire - Extruded PTFE Insulation
(11) M22759/9 wires have extruded PTFE insulation for high-temperature applications where the additional abrasion resistance of mineral-filled PTFE insulation is not required.These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. For versions of these wires with thinner-wall insulation and 600V voltage rating, see M22759/11 and /12. 0000083295_008.jpgM22759/10 Wire - Extruded PTFE Insulation
(11) M22759/10 wires have extruded PTFE insulation for high-temperature applications where the additional abrasion resistance of mineral-filled PTFE insulation is not required.These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. For versions of these wires with thinner-wall insulation and 600V voltage rating, see M22759/11 and /12. 0000083295_008.jpgM22759/11 Wire - Extruded PTFE Insulation
(11) M22759/11 wires have extruded PTFE isulation for high-temperature applications where the additional abrasion resistance of mineral-filled PTFE insulation is not required.These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. These wires are similar to M22759/9 and /10 wires, but have a thinner-wall insulation and 600V voltage rating. 0000083295_008.jpgM22759/12 Wire - Extruded PTFE Insulation
(11) M22759/12 wires have extruded PTFE isulation for high-temperature applications where the additional abrasion resistance of mineral-filled PTFE insulation is not required.These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. These wires are similar to M22759/9 and /10 wires, but have a thinner-wall insulation and 600V voltage rating. 0000083295_008.jpgM22759/16 Wire - Extruded ETFE Insulation
(15) M22759/16 wires have extruded ETFE insulation for aerospace and other applications requiring light weight, tight diameter tolerances, and enhanced mechanical toughness. ETFE insulation also provides exceptional resistance to radiation and chemicals. For versions of these wires with thinner-wall insulation for light weight, see M22759/18 and /19 0000083295_008.jpgM22759/17 Wire - Extruded ETFE Insulation
(4) M22759/17 wires have extruded ETFE insulation for aerospace and other applications requiring light weight, tight diameter tolerances, and enhanced mechanical toughness. ETFE insulation also provides exceptional resistance to radiation and chemicals. For versions of these wires with thinner-wall insulation for light weight, see M22759/18 and /19 0000083295_008.jpgM22759/18 Wire - Extruded Thin-wall ETFE Insulation
(9) M22759/18 wires have thin-wall extruded ETFE insulation for aerospace and other applications requiring light weight, tight diameter tolerances, and enhanced mechanical toughness. ETFE insulation also provides exceptional resistance to radiation and chemicals. 0000083295_008.jpgM22759/19 Wire - Thin-wall ETFE Insulation
(4) M22759/19 wires have thin-wall extruded ETFE insulation for aerospace and other applications requiring light weight, tight diameter tolerances, and enhanced mechanical toughness. ETFE insulation also provides exceptional resistance to radiation and chemicals. 0000083295_008.jpgM22759/20 Wire - High-strength Conductor
(5) M22759/20 wires have extruded PTFE insulation and a high-strength copper alloy conductor for greater break strength.They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. For versions of these wires with thinner-wall insulation and 600V voltage rating, see M22759/22 and /23 0000083295_008.jpgM22759/21 Wire - High-strength Conductor
(5) M22759/21 wires have extruded PTFE insulation and a high-strength copper alloy conductor for greater break strength.They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. For versions of these wires with thinner-wall insulation and 600V voltage rating, see M22759/22 and /23 0000083295_008.jpgM22759/22 Wire - High-strength Conductor
(5) M22759/22 wires have thin-wall extruded PTFE insulation and a high-strength copper alloy conductor for greater break strength. They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. 0000083295_008.jpgM22759/23 Wire - High-strength Conductor
(5) M22759/23 wires have thin-wall extruded PTFE insulation and a high-strength copper alloy conductor for greater break strength. They are ideal for aerospace and other applications requiring high reliability and break strength, enhanced flex life, and resistance to high temperatures. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. 0000083295_008.jpgM22759/28 Wire - PTFE/Polyimide Insulation
(8) M22759/28 wires have extruded PTFE insulation with a polyimide hard coat for increased cut-through and abrasion resistance. These wires are designed for aerospace and other applications requiring excellent thermal stability, tight dimensional tolerances, and high reliability. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. For versions of these wires with high-strength copper alloy conductor, see M22759/30 and /31. 0000083295_008.jpgM22759/29 Wire - PTFE/Polyimide Insulation
(8) M22759/29 wires have extruded PTFE insulation with a polyimide hard coat for increased cut-through and abrasion resistance. These wires are designed for aerospace and other applications requiring excellent thermal stability, tight dimensional tolerances, and high reliability. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. For versions of these wires with high-strength copper alloy conductor, see M22759/30 and /31. 0000083295_008.jpgM22759/30 Wire - High-strength Conductor
(5) MIL-DTL-M22759/30 wires have extruded PTFE insulation with a polyimide hard coat for increased cut-through and abrasion resistance, and a high-strength copper alloy conductor for greater break strength. These wires are designed for aerospace and other applications requiring excellent thermal stability, tight dimensional tolerances, and high reliability. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. 0000083295_008.jpgM22759/31 Wire - High-strength Conductor
(5) MIL-DTL-M22759/30 wires have extruded PTFE insulation with a polyimide hard coat for increased cut-through and abrasion resistance, and a high-strength copper alloy conductor for greater break strength. These wires are designed for aerospace and other applications requiring excellent thermal stability, tight dimensional tolerances, and high reliability. These wires are especially well-suited in applications where smoke emission, overload stability, and flammability are major concerns. 0000083295_008.jpgSAE-AS22759/32 MIL/Aero Wire & Cables
(10) Tinned Copper Conductor150°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/33 MIL/Aero Wire & Cables
(6) Silver Coated High Strength Copper Alloy Conductor200°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/34 MIL/Aero Wire & Cables
(15) Tinned Copper Conductor150°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/35 MIL/Aero Wire & Cables
(4) Silver Coated High Strength Copper Alloy Conductor200°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/41 MIL/Aero Wire & Cables
(16) Nickel Coated Copper Conductor200°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/42 MIL/Aero Wire & Cables
(4) Nickel Coated High Strength Copper Conductor200°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/43 MIL/Aero Wire & Cables
(16) Silver Coated Copper Conductor200°C 600 Volts
Dual Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/44 MIL/Aero Wire & Cables
(9) Silver Coated Copper Conductor200°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/45 MIL/Aero Wire & Cables
(9) Nickel Coated Copper Conductor200°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg
SAE-AS22759/46 MIL/Aero Wire & Cables
(5) Nickel Coated High Strength Copper Alloy Conductor200°C 600 Volts
Single Insulation of Cross-linked Ethylene-Tetrafluoroethylene (ETFE)
Note: SAE-AS22759 was formally Mil-W or Mil-DTL-M22759. Although the beginning nomenclature has been changed to identify the new governing body, the products themselves remain mostly unchanged. SAE-AS-22759-33.jpg